From f35b55565a4932739350065bce57ec0f67fcd54b Mon Sep 17 00:00:00 2001 From: Philippe CORNU Date: Mon, 22 Jan 2018 16:35:47 +0100 Subject: [PATCH] dt-bindings: display: stm32: correct clock-names in dsi panel example In the dsi panel example, clock names in the "clock-names" field have been swapped: * "pclk" (peripheral clock) is <&rcc 1 CLK_F469_DSI> on stm32f4 * "ref" (dsi phy pll ref clock) is <&clk_hse> on stm32f4 Signed-off-by: Philippe Cornu Reviewed-by: Rob Herring Signed-off-by: Benjamin Gaignard Link: https://patchwork.freedesktop.org/patch/msgid/20180122153547.23470-1-philippe.cornu@st.com --- Documentation/devicetree/bindings/display/st,stm32-ltdc.txt | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/Documentation/devicetree/bindings/display/st,stm32-ltdc.txt b/Documentation/devicetree/bindings/display/st,stm32-ltdc.txt index 029252253ad4..3eb1b48b47dd 100644 --- a/Documentation/devicetree/bindings/display/st,stm32-ltdc.txt +++ b/Documentation/devicetree/bindings/display/st,stm32-ltdc.txt @@ -98,7 +98,7 @@ Example 2: DSI panel compatible = "st,stm32-dsi"; reg = <0x40016c00 0x800>; clocks = <&rcc 1 CLK_F469_DSI>, <&clk_hse>; - clock-names = "ref", "pclk"; + clock-names = "pclk", "ref"; resets = <&rcc STM32F4_APB2_RESET(DSI)>; reset-names = "apb"; -- 2.30.2