From e702c66c0724c09e8efb87cb6fff8100e988cdb0 Mon Sep 17 00:00:00 2001 From: H Hartley Sweeten Date: Thu, 17 Apr 2014 10:08:02 -0700 Subject: [PATCH] staging: comedi: ni_pcidio: fix the cmd->start_arg use for TRIG_INT This driver only a cmd->start_src of TRIG_NOW or TRIG_INT. The cmd->start_arg is trivially validated for both sources to be 0. For a TRIG_INT source, the cmd->start_arg is actually the valid trig_num that is passed to the async (*inttrig) callback. Refactor the (*inttrig) function so that the cmd->start_arg is used to check the trig_num instead of the open coded value. Signed-off-by: H Hartley Sweeten Reviewed-by: Ian Abbott Signed-off-by: Greg Kroah-Hartman --- drivers/staging/comedi/drivers/ni_pcidio.c | 6 ++++-- 1 file changed, 4 insertions(+), 2 deletions(-) diff --git a/drivers/staging/comedi/drivers/ni_pcidio.c b/drivers/staging/comedi/drivers/ni_pcidio.c index 85ac2d964f5c..962c2353a79f 100644 --- a/drivers/staging/comedi/drivers/ni_pcidio.c +++ b/drivers/staging/comedi/drivers/ni_pcidio.c @@ -773,11 +773,13 @@ static int setup_mite_dma(struct comedi_device *dev, struct comedi_subdevice *s) } static int ni_pcidio_inttrig(struct comedi_device *dev, - struct comedi_subdevice *s, unsigned int trignum) + struct comedi_subdevice *s, + unsigned int trig_num) { struct nidio96_private *devpriv = dev->private; + struct comedi_cmd *cmd = &s->async->cmd; - if (trignum != 0) + if (trig_num != cmd->start_arg) return -EINVAL; writeb(devpriv->OpModeBits, devpriv->mite->daq_io_addr + OpMode); -- 2.30.2