From 830c7b6722c6a9762411bf52a7bf2fae4dc71dab Mon Sep 17 00:00:00 2001 From: Ben Warren Date: Mon, 9 Nov 2009 11:43:18 -0800 Subject: [PATCH] Fix CS8900 regression on impa7 board The following error was seen on impa7 board, due to its use of a 32-bit bus on CS8900. cs8900.c:137:37: error: macro "get_reg_init_bus" passed 2 arguments, but takes just 1 This patch gives the macro the correct number of arguments Signed-off-by: Ben Warren --- drivers/net/cs8900.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/drivers/net/cs8900.c b/drivers/net/cs8900.c index a9d1f22734..df360042be 100644 --- a/drivers/net/cs8900.c +++ b/drivers/net/cs8900.c @@ -56,7 +56,7 @@ #define REG_READ(a) readl((a)) /* we don't need 16 bit initialisation on 32 bit bus */ -#define get_reg_init_bus(x) get_reg((x)) +#define get_reg_init_bus(r,d) get_reg((r),(d)) #else -- 2.30.2