From 469518a3455c79619e9231aeffeffa2e2989f738 Mon Sep 17 00:00:00 2001 From: NeilBrown Date: Mon, 31 Jan 2011 11:57:43 +1100 Subject: [PATCH] md: fix the test for finding spares in raid5_start_reshape. As spares can be added to the array before the reshape is started, we need to find and count them when checking there are enough. The array could have been degraded, so we need to check all devices, no just those out side of the range of devices in the array before the reshape. So instead of checking the index, check the In_sync flag as that reliably tells if the device is a spare or this purpose. Signed-off-by: NeilBrown --- drivers/md/raid5.c | 4 ++-- 1 file changed, 2 insertions(+), 2 deletions(-) diff --git a/drivers/md/raid5.c b/drivers/md/raid5.c index fa5519389a17..a6d2c3ddeee4 100644 --- a/drivers/md/raid5.c +++ b/drivers/md/raid5.c @@ -5526,8 +5526,8 @@ static int raid5_start_reshape(mddev_t *mddev) return -ENOSPC; list_for_each_entry(rdev, &mddev->disks, same_set) - if ((rdev->raid_disk < 0 || rdev->raid_disk >= conf->raid_disks) - && !test_bit(Faulty, &rdev->flags)) + if (!test_bit(In_sync, &rdev->flags) + && !test_bit(Faulty, &rdev->flags)) spares++; if (spares - mddev->degraded < mddev->delta_disks - conf->max_degraded) -- 2.30.2