From: Adrian Bunk Date: Thu, 26 Jun 2008 10:38:13 +0000 (+0300) Subject: build algorithms into the mac80211 module X-Git-Url: http://git.lede-project.org./?a=commitdiff_plain;h=e5f5e7339cd95d07937e6f8081b46fba86c742a7;p=openwrt%2Fstaging%2Fblogic.git build algorithms into the mac80211 module The old infrastructure was: - the default algorithm is built into mac80211 - other algorithms get into their own modules The implementation of this complicated scheme was horrible (just look at net/mac80211/Makefile), and anyone adding a new algorithm would most likely not get it right at his first attempt. This patch therefore builds all enabled algorithms into the mac80211 module. The user interface for the rate control algorithms changes as follows: - first the user can choose which algorithms to enable (currently only MAC80211_RC_PID is available) - if more than one algorithm is enabled (currently not possible since only one algorithm is present) the user then chooses the default one Note: - MAC80211_RC_PID is always enables for CONFIG_EMBEDDED=n Technical changes: - all selected algorithms get into the mac80211 module - net/mac80211/Makefile can now become much less complicated - support for rc80211_pid_algo.c being modular is no longer required - this includes unexporting mesh_plink_broken Signed-off-by: Adrian Bunk Signed-off-by: John W. Linville --- diff --git a/net/mac80211/Kconfig b/net/mac80211/Kconfig index 594bc7319ca6..661d3c291482 100644 --- a/net/mac80211/Kconfig +++ b/net/mac80211/Kconfig @@ -27,6 +27,14 @@ comment "QoS/HT support needs CONFIG_NETDEVICES_MULTIQUEUE" menu "Rate control algorithm selection" depends on MAC80211 != n +config MAC80211_RC_PID + bool "PID controller based rate control algorithm" if EMBEDDED + default y + ---help--- + This option enables a TX rate control algorithm for + mac80211 that uses a PID controller to select the TX + rate. + choice prompt "Default rate control algorithm" default MAC80211_RC_DEFAULT_PID @@ -38,40 +46,19 @@ choice config MAC80211_RC_DEFAULT_PID bool "PID controller based rate control algorithm" - select MAC80211_RC_PID + depends on MAC80211_RC_PID ---help--- Select the PID controller based rate control as the default rate control algorithm. You should choose this unless you know what you are doing. -config MAC80211_RC_DEFAULT_NONE - bool "No default algorithm" - depends on EMBEDDED - help - Selecting this option will select no default algorithm - and allow you to not build any. Do not choose this - option unless you know your driver comes with another - suitable algorithm. endchoice -comment "Selecting 'y' for an algorithm will" -comment "build the algorithm into mac80211." - config MAC80211_RC_DEFAULT string default "pid" if MAC80211_RC_DEFAULT_PID default "" -config MAC80211_RC_PID - tristate "PID controller based rate control algorithm" - ---help--- - This option enables a TX rate control algorithm for - mac80211 that uses a PID controller to select the TX - rate. - - Say Y or M unless you're sure you want to use a - different rate control algorithm. - endmenu config MAC80211_MESH diff --git a/net/mac80211/Makefile b/net/mac80211/Makefile index 1d2a4e010e5c..fa47438e338f 100644 --- a/net/mac80211/Makefile +++ b/net/mac80211/Makefile @@ -1,13 +1,5 @@ obj-$(CONFIG_MAC80211) += mac80211.o -# objects for PID algorithm -rc80211_pid-y := rc80211_pid_algo.o -rc80211_pid-$(CONFIG_MAC80211_DEBUGFS) += rc80211_pid_debugfs.o - -# build helper for PID algorithm -rc-pid-y := $(rc80211_pid-y) -rc-pid-m := rc80211_pid.o - # mac80211 objects mac80211-y := \ main.o \ @@ -42,10 +34,8 @@ mac80211-$(CONFIG_MAC80211_MESH) += \ mesh_plink.o \ mesh_hwmp.o +# objects for PID algorithm +rc80211_pid-y := rc80211_pid_algo.o +rc80211_pid-$(CONFIG_MAC80211_DEBUGFS) += rc80211_pid_debugfs.o -# Build rate control algorithm(s) -CFLAGS_rc80211_pid_algo.o += -DRC80211_PID_COMPILE -mac80211-$(CONFIG_MAC80211_RC_PID) += $(rc-pid-$(CONFIG_MAC80211_RC_PID)) - -# Modular rate algorithms are assigned to mac80211-m - make separate modules -obj-m += $(mac80211-m) +mac80211-$(CONFIG_MAC80211_RC_PID) += $(rc80211_pid-y) diff --git a/net/mac80211/mesh_pathtbl.c b/net/mac80211/mesh_pathtbl.c index 947b13b40726..5f88a2e6ee50 100644 --- a/net/mac80211/mesh_pathtbl.c +++ b/net/mac80211/mesh_pathtbl.c @@ -262,7 +262,6 @@ void mesh_plink_broken(struct sta_info *sta) } rcu_read_unlock(); } -EXPORT_SYMBOL(mesh_plink_broken); /** * mesh_path_flush_by_nexthop - Deletes mesh paths if their next hop matches diff --git a/net/mac80211/rate.h b/net/mac80211/rate.h index 0ed9c8a2f56f..ede7ab56f65b 100644 --- a/net/mac80211/rate.h +++ b/net/mac80211/rate.h @@ -162,9 +162,7 @@ void rate_control_deinitialize(struct ieee80211_local *local); /* Rate control algorithms */ -#if defined(RC80211_PID_COMPILE) || \ - (defined(CONFIG_MAC80211_RC_PID) && \ - !defined(CONFIG_MAC80211_RC_PID_MODULE)) +#ifdef CONFIG_MAC80211_RC_PID extern int rc80211_pid_init(void); extern void rc80211_pid_exit(void); #else diff --git a/net/mac80211/rc80211_pid_algo.c b/net/mac80211/rc80211_pid_algo.c index e8945413e4a2..62388f8e9024 100644 --- a/net/mac80211/rc80211_pid_algo.c +++ b/net/mac80211/rc80211_pid_algo.c @@ -540,11 +540,6 @@ static struct rate_control_ops mac80211_rcpid = { #endif }; -MODULE_DESCRIPTION("PID controller based rate control algorithm"); -MODULE_AUTHOR("Stefano Brivio"); -MODULE_AUTHOR("Mattias Nissler"); -MODULE_LICENSE("GPL"); - int __init rc80211_pid_init(void) { return ieee80211_rate_control_register(&mac80211_rcpid); @@ -554,8 +549,3 @@ void rc80211_pid_exit(void) { ieee80211_rate_control_unregister(&mac80211_rcpid); } - -#ifdef CONFIG_MAC80211_RC_PID_MODULE -module_init(rc80211_pid_init); -module_exit(rc80211_pid_exit); -#endif