PKG_NAME:=nut
PKG_VERSION:=2.7.4
-PKG_RELEASE:=7
+PKG_RELEASE:=8
PKG_SOURCE:=$(PKG_NAME)-$(PKG_VERSION).tar.gz
PKG_SOURCE_URL:=http://www.networkupstools.org/source/2.7/
endef
define Package/nut-server/install
+ # Server portion
$(INSTALL_DIR) $(1)/etc/nut
$(INSTALL_DIR) $(1)/usr/sbin
$(INSTALL_DIR) $(1)/etc/init.d
$(INSTALL_DIR) $(1)/usr/share/nut
- $(INSTALL_DIR) $(1)/etc/init.d
$(INSTALL_BIN) ./files/nut-server.init $(1)/etc/init.d/nut-server
$(INSTALL_BIN) $(PKG_INSTALL_DIR)/usr/sbin/upsd $(1)/usr/sbin
- $(INSTALL_BIN) $(PKG_INSTALL_DIR)/usr/sbin/upsdrvctl $(1)/usr/sbin
$(INSTALL_BIN) $(PKG_INSTALL_DIR)/usr/share/nut/cmdvartab $(1)/usr/share/nut/
- $(INSTALL_BIN) $(PKG_INSTALL_DIR)/usr/share/nut/driver.list $(1)/usr/share/nut/
$(INSTALL_DIR) $(1)/etc/config
$(INSTALL_CONF) ./files/nut_server $(1)/etc/config/nut_server
- ln -sf /var/etc/nut/nut.conf $(1)/etc/nut/nut.conf
- ln -sf /var/etc/nut/ups.conf $(1)/etc/nut/ups.conf
ln -sf /var/etc/nut/upsd.users $(1)/etc/nut/upsd.users
ln -sf /var/etc/nut/upsd.conf $(1)/etc/nut/upsd.conf
+ # Driver common portion
+ $(INSTALL_BIN) $(PKG_INSTALL_DIR)/usr/sbin/upsdrvctl $(1)/usr/sbin
+ $(INSTALL_BIN) $(PKG_INSTALL_DIR)/usr/share/nut/driver.list $(1)/usr/share/nut/
+ ln -sf /var/etc/nut/ups.conf $(1)/etc/nut/ups.conf
endef
define Package/nut-common
This package contains the common files.
endef
+define Package/nut-common/conffiles
+/etc/nut/nut.conf
+endef
+
define Package/nut-common/install
$(INSTALL_DIR) $(1)/etc/nut
$(INSTALL_DIR) $(1)/usr/lib
$(call Package/nut/Default)
TITLE+= (server)
DEPENDS:=nut +nut-common
+ USERID:=nut=113:nut=113
endef
define Package/nut-server/description
define Package/nut-server/conffiles
/etc/config/nut_server
+/etc/nut/upsd.conf
+/etc/nut/upsd.users
+/etc/nut/ups.conf
endef
define Package/nut-upsmon
define Package/nut-upsmon/conffiles
/etc/config/nut_monitor
+/etc/nut/upsmon.conf
endef
define Package/nut-upsmon/install
$(INSTALL_DIR) $(1)/etc/init.d
$(INSTALL_BIN) ./files/nut-monitor.init $(1)/etc/init.d/nut-monitor
$(INSTALL_BIN) $(PKG_INSTALL_DIR)/usr/sbin/upsmon $(1)/usr/sbin/
+ $(INSTALL_BIN) ./files/nutshutdown $(1)/usr/sbin/nutshutdown
$(INSTALL_DIR) $(1)/etc/config
$(INSTALL_CONF) ./files/nut_monitor $(1)/etc/config/nut_monitor
ln -sf /var/etc/nut/upsmon.conf $(1)/etc/nut/upsmon.conf
define Package/nut-driver-$(2)
$(call Package/nut/Default)
TITLE:=$(2) (NUT $(1) driver)
- DEPENDS:=nut +nut-common
+ DEPENDS:=nut +nut-server
$(if $(filter $(1),snmp),DEPENDS+= @NUT_DRIVER_SNMP)
$(if $(filter $(1),usb),DEPENDS+= @NUT_DRIVER_USB)
$(if $(filter $(1),serial),DEPENDS+= @NUT_DRIVER_SERIAL)
system="$system:$port";
fi
config_get displayname "$cfg" displayname
- echo "MONITOR $system \"$displayname\"" >> $UPSCGI_C
+ echo "MONITOR $system \"$displayname\"" >> "$UPSCGI_C"
}
start() {
#!/bin/sh /etc/rc.common
-START=60
+START=51
USE_PROCD=1
UPSMON_C=/var/etc/nut/upsmon.conf
nut_upsmon_conf() {
local cfg="$1"
- echo "# Config file automatically generated from UCI config" > $UPSMON_C
+ echo "# Config file automatically generated from UCI config" > "$UPSMON_C"
config_get runas "$cfg" runas "nut"
[ -n "$runas" ] && echo "RUN_AS_USER $runas" >> $UPSMON_C
config_get val "$cfg" minsupplies 1
- echo "MINSUPPLIES $val" >> $UPSMON_C
+ echo "MINSUPPLIES $val" >> "$UPSMON_C"
- config_get val "$cfg" shutdowncmd "/sbin/halt"
- echo "SHUTDOWNCMD \"$val\"" >> $UPSMON_C
+ config_get val "$cfg" shutdowncmd "/usr/sbin/nutshutdown"
+ echo "SHUTDOWNCMD \"$val\"" >> "$UPSMON_C"
config_get val "$cfg" notifycmd
- [ -n "$val" ] && echo "NOTIFYCMD \"$val\"" >> $UPSMON_C
+ [ -n "$val" ] && echo "NOTIFYCMD \"$val\"" >> "$UPSMON_C"
config_get val "$cfg" pollfreq 5
- echo "POLLFREQ $val" >> $UPSMON_C
+ echo "POLLFREQ $val" >> "$UPSMON_C"
config_get val "$cfg" pollfreqalert 5
- echo "POLLFREQALERT $val" >> $UPSMON_C
+ echo "POLLFREQALERT $val" >> "$UPSMON_C"
config_get val "$cfg" hostsync 15
- echo "HOSTSYNC $val" >> $UPSMON_C
+ echo "HOSTSYNC $val" >> "$UPSMON_C"
config_get val "$cfg" deadtime 15
- echo "DEADTIME $val" >> $UPSMON_C
+ echo "DEADTIME $val" >> "$UPSMON_C"
- config_get val "$cfg" powerdownflag /var/run/killpower
- echo "POWERDOWNFLAG $val" >> $UPSMON_C
+ echo "POWERDOWNFLAG /var/run/killpower" >> "$UPSMON_C"
config_get val "$cfg" onlinemsg
- [ -n "$val" ] && echo "NOTIFYMSG ONLINE \"$val\"" >> $UPSMON_C
+ [ -n "$val" ] && echo "NOTIFYMSG ONLINE \"$val\"" >> "$UPSMON_C"
config_get val "$cfg" onbattmsg
- [ -n "$val" ] && echo "NOTIFYMSG ONBATT \"$val\"" >> $UPSMON_C
+ [ -n "$val" ] && echo "NOTIFYMSG ONBATT \"$val\"" >> "$UPSMON_C"
config_get val "$cfg" lowbattmsg
- [ -n "$val" ] && echo "NOTIFYMSG LOWBATT \"$val\"" >> $UPSMON_C
+ [ -n "$val" ] && echo "NOTIFYMSG LOWBATT \"$val\"" >> "$UPSMON_C"
config_get val "$cfg" fsdmsg
- [ -n "$val" ] && echo "NOTIFYMSG FSD \"$val\"" >> $UPSMON_C
+ [ -n "$val" ] && echo "NOTIFYMSG FSD \"$val\"" >> "$UPSMON_C"
config_get val "$cfg" commokmsg
- [ -n "$val" ] && echo "NOTIFYMSG COMMOK \"$val\"" >> $UPSMON_C
+ [ -n "$val" ] && echo "NOTIFYMSG COMMOK \"$val\"" >> "$UPSMON_C"
config_get val "$cfg" commbadmsg
- [ -n "$val" ] && echo "NOTIFYMSG COMMBAD \"$val\"" >> $UPSMON_C
+ [ -n "$val" ] && echo "NOTIFYMSG COMMBAD \"$val\"" >> "$UPSMON_C"
config_get val "$cfg" shutdownmsg
- [ -n "$val" ] && echo "NOTIFYMSG SHUTDOWN \"$val\"" >> $UPSMON_C
+ [ -n "$val" ] && echo "NOTIFYMSG SHUTDOWN \"$val\"" >> "$UPSMON_C"
config_get val "$cfg" replbattmsg
- [ -n "$val" ] && echo "NOTIFYMSG REPLBATT \"$val\"" >> $UPSMON_C
+ [ -n "$val" ] && echo "NOTIFYMSG REPLBATT \"$val\"" >> "$UPSMON_C"
config_get val "$cfg" nocommmsg
- [ -n "$val" ] && echo "NOTIFYMSG NOCOMM \"$val\"" >> $UPSMON_C
+ [ -n "$val" ] && echo "NOTIFYMSG NOCOMM \"$val\"" >> "$UPSMON_C"
config_get val "$cfg" noparentmsg
- [ -n "$val" ] && echo "NOTIFYMSG NOPARENT \"$val\"" >> $UPSMON_C
+ [ -n "$val" ] && echo "NOTIFYMSG NOPARENT \"$val\"" >> "$UPSMON_C"
notifylist() {
local value="$1"
val=""
config_list_foreach "$cfg" defaultnotify notifylist
default="$optval"
- echo "NOTIFYFLAG ONLINE $(setnotify "$cfg" onlinenotify)" >> $UPSMON_C
- echo "NOTIFYFLAG ONBATT $(setnotify "$cfg" onbattnotify)" >> $UPSMON_C
- echo "NOTIFYFLAG LOWBATT $(setnotify "$cfg" lowbatnotify)" >> $UPSMON_C
- echo "NOTIFYFLAG FSD $(setnotify "$cfg" fsdnotify)" >> $UPSMON_C
- echo "NOTIFYFLAG COMMOK $(setnotify "$cfg" commoknotify)" >> $UPSMON_C
- echo "NOTIFYFLAG COMMBAD $(setnotify "$cfg" commbadnotify)" >> $UPSMON_C
- echo "NOTIFYFLAG SHUTDOWN $(setnotify "$cfg" shutdownnotify)" >> $UPSMON_C
- echo "NOTIFYFLAG REPLBATT $(setnotify "$cfg" repolbattnotify)" >> $UPSMON_C
- echo "NOTIFYFLAG NOCOMM $(setnotify "$cfg" nocommnotify)" >> $UPSMON_C
- echo "NOTIFYFLAG NOPARENT $(setnotify "$cfg" noparentnotify)" >> $UPSMON_C
+ echo "NOTIFYFLAG ONLINE $(setnotify "$cfg" onlinenotify)" >> "$UPSMON_C"
+ echo "NOTIFYFLAG ONBATT $(setnotify "$cfg" onbattnotify)" >> "$UPSMON_C"
+ echo "NOTIFYFLAG LOWBATT $(setnotify "$cfg" lowbatnotify)" >> "$UPSMON_C"
+ echo "NOTIFYFLAG FSD $(setnotify "$cfg" fsdnotify)" >> "$UPSMON_C"
+ echo "NOTIFYFLAG COMMOK $(setnotify "$cfg" commoknotify)" >> "$UPSMON_C"
+ echo "NOTIFYFLAG COMMBAD $(setnotify "$cfg" commbadnotify)" >> "$UPSMON_C"
+ echo "NOTIFYFLAG SHUTDOWN $(setnotify "$cfg" shutdownnotify)" >> "$UPSMON_C"
+ echo "NOTIFYFLAG REPLBATT $(setnotify "$cfg" repolbattnotify)" >> "$UPSMON_C"
+ echo "NOTIFYFLAG NOCOMM $(setnotify "$cfg" nocommnotify)" >> "$UPSMON_C"
+ echo "NOTIFYFLAG NOPARENT $(setnotify "$cfg" noparentnotify)" >> "$UPSMON_C"
config_get val "$cfg" rbwarntime 43200
- echo "RBWARNTIME $val" >> $UPSMON_C
+ echo "RBWARNTIME $val" >> "$UPSMON_C"
config_get val "$cfg" nocommwarntime 300
- echo "NOCOMMWARNTIME $val" >> $UPSMON_C
+ echo "NOCOMMWARNTIME $val" >> "$UPSMON_C"
config_get val "$cfg" finaldelay 5
- echo "FINALDELAY $val" >> $UPSMON_C
+ echo "FINALDELAY $val" >> "$UPSMON_C"
config_get val "$cfg" certpath
- if [ -n "$val" ]; then echo "CERTPATH $val" >> $UPSMON_C; fi
+ if [ -n "$val" ]; then echo "CERTPATH $val" >> "$UPSMON_C"; fi
config_get_bool val "$cfg" certverify 0
- if [ -n "$val" ]; then echo "CERTVERIFY $val" >> $UPSMON_C; fi
+ if [ -n "$val" ]; then echo "CERTVERIFY $val" >> "$UPSMON_C"; fi
config_get_bool val "$cfg" forcessl 0
- if [ -n "$val" ]; then echo "FORCESSL $val" >> $UPSMON_C; fi
+ if [ -n "$val" ]; then echo "FORCESSL $val" >> "$UPSMON_C"; fi
+
+ havemon=1
}
nut_upsmon_add() {
local password
local system
- # if UPSMON_C is a symlink we're only doing generated config
- [ -L $UPSMON_C ] && {
- rm -f $UPSMON_C
- nut_upsmon_conf ""
- }
-
config_get upsname "$cfg" upsname
config_get hostname "$cfg" hostname localhost
config_get port "$cfg" port
if [ -n "$port" ]; then
system="$system:$port";
fi
- echo "MONITOR $system $powervalue $username $password $type" >> $UPSMON_C
+ echo "MONITOR $system $powervalue $username $password $type" >> "$UPSMON_C"
+
+ havems=1
}
-start_service() {
- mkdir -p "$(dirname "$UPSMON_C")"
- chmod 750 "$(dirname "$UPSMON_C")"
+build_config() {
+ local runas
+ mkdir -m 0750 -p "$(dirname "$UPSMON_C")"
config_load nut_monitor
-
config_foreach nut_upsmon_conf upsmon
config_foreach nut_upsmon_add master master
config_foreach nut_upsmon_add slave slave
- [ -z "$(cat /var/etc/nut/nut.conf)" ] && echo "MODE=netclient" >>/var/etc/nut/nut.conf
-
- chmod 640 $UPSMON_C
- chmod 640 /var/etc/nut/nut.conf
-
- chown ${runas:-root}:$(id -gn ${runas:-root}) /var/etc/nut
- chown ${runas:-root}:$(id -gn ${runas:-root}) /var/etc/nut/nut.conf
- chown ${runas:-root}:$(id -gn ${runas:-root}) $UPSMON_C
-
- [ -d /var/run/nut ] || {
- mkdir -m 0750 -p /var/run/nut
- chown ${runas:-root}:$(id -gn ${runas:-root}) /var/run/nut
+ [ ! -s "$(cat /var/etc/nut/nut.conf)" ] && {
+ echo "MODE=netclient" >>/var/etc/nut/nut.conf
+ chmod 640 /var/etc/nut/nut.conf
+ chgrp $(id -gn ${runas:-root}) /var/etc/nut/nut.conf
}
- exec $DEBUG /usr/sbin/upsmon $UPSMON_OPTIONS
+ [ -s "$UPSMON_C" ] && chmod 640 "$UPSMON_C"
+ [ -s "$UPSMON_C" ] && chgrp $(id -gn ${runas:-root}) "$UPSMON_C"
}
-stop_service() {
- exec /usr/sbin/upsmon -c stop
+start_service() {
+ local havemon havems
+ build_config
+
+ [ "$havemon" != 1 ] && return
+ [ "$havems" != 1 ] && return
+
+ procd_open_instance "upsmon"
+ procd_set_param respawn
+ procd_set_param stderr 0
+ procd_set_param stdout 1
+ procd_set_param command /usr/sbin/upsmon -D
+ procd_close_instance
}
reload_service() {
- exec /usr/sbin/upsmon -c reload
+ if pgrep upsmon >/dev/null 2>/dev/null; then
+ build_config
+ /usr/sbin/upsmon -c reload
+ else
+ stop
+ sleep 2
+ start_service
+ fi
+}
+
+service_triggers() {
+ procd_add_reload_trigger "nut_monitor"
}
#
START=50
-RUN_D=/var/run
-PID_F=$RUN_D/upsd.pid
-UPS_C=/var/etc/nut/ups.conf
USERS_C=/var/etc/nut/upsd.users
UPSD_C=/var/etc/nut/upsd.conf
+UPS_C=/var/etc/nut/ups.conf
USE_PROCD=1
-listen_address() {
- local cfg="$1"
+get_write_driver_config() {
+ local cfg="$1"
+ local var="$2"
+ local def="$3"
+ local flag="$4"
+ local val
- config_get address "$cfg" address "::1"
- config_get port "$cfg" port
- echo "LISTEN $address $port" >>$UPSD_C
+ [ -z "$flag" ] && {
+ config_get val "$cfg" "$var" "$def"
+ [ -n "$val" ] && [ "$val" != "0" ] && echo "$var = $val" >>"$UPS_C"
+ }
+
+ [ -n "$flag" ] && {
+ config_get_bool val "$cfg" "$var" "$def"
+ [ "$val" = 1 ] && echo "$var" >>"$UPS_C"
+ }
}
upsd_statepath() {
+ local cfg="$1"
+ local statepath
+
+ config_get statepath "$cfg" statepath "/var/run/nut"
+ STATEPATH="$statepath"
+}
+
+upsd_runas() {
+ local cfg="$1"
+ local runas
+
+ [ -n "$RUNAS" ] && return
+
+ config_get runas "$cfg" runas "nut"
+ RUNAS="$runas"
+}
+
+listen_address() {
local cfg="$1"
- config_get statepath "$cfg" statepath
+
+ config_get address "$cfg" address "::1"
+ config_get port "$cfg" port
+ echo "LISTEN $address $port" >>"$UPSD_C"
}
upsd_config() {
local cfg="$1"
- local maxage maxconn certfile
+ local maxage maxconn certfile runas statepath
# Note runas support requires you make sure USB device file is readable by
# the runas user
- config_get runas "$cfg" runas
+ config_get runas "$cfg" runas "nut"
+ RUNAS="$runas"
+
+ config_get statepath "$cfg" statepath "/var/run/nut"
+ STATEPATH="$statepath"
config_get maxage "$cfg" maxage
- [ -n "$maxage" ] && echo "MAXAGE $maxage" >>$UPSD_C
+ [ -n "$maxage" ] && echo "MAXAGE $maxage" >>"$UPSD_C"
- config_get statepath "$cfg" statepath
- [ -n "$statepath" ] && echo "STATEPATH $statepath" >>$UPSD_C
+ [ -n "$statepath" ] && echo "STATEPATH $statepath" >>"$UPSD_C"
config_get maxconn "$cfg" maxconn
- [ -n "$maxconn" ] && echo "MAXCONN $maxconn" >>$UPSD_C
+ [ -n "$maxconn" ] && echo "MAXCONN $maxconn" >>"$UPSD_C"
#NOTE: certs only apply to SSL-enabled version
config_get certfile "$cfg" certfile
- [ -n "$certfile" ] && echo "CERTFILE $certfile" >>$UPSD_C
+ [ -n "$certfile" ] && echo "CERTFILE $certfile" >>"$UPSD_C"
}
nut_user_add() {
local val
config_get val "$cfg" username "$1"
- echo "[$val]" >> $USERS_C
+ echo "[$val]" >> "$USERS_C"
config_get val "$cfg" password
- echo " password = $val" >> $USERS_C
+ echo " password = $val" >> "$USERS_C"
config_get val "$cfg" actions
for a in $val; do
- echo " actions = $a" >> $USERS_C
+ echo " actions = $a" >> "$USERS_C"
done
instcmd() {
local val="$1"
- echo " instcmds = $val" >> $USERS_C
+ echo " instcmds = $val" >> "$USERS_C"
}
config_list_foreach "$cfg" instcmd instcmd
config_get val "$cfg" upsmon
if [ -n "$val" ]; then
- echo " upsmon $val" >> $USERS_C
+ echo " upsmon $val" >> "$USERS_C"
fi
}
-start_service() {
- local runas statepath
-
- mkdir -p /var/etc/nut
- chmod -R 750 /var/etc/nut
-
- rm -f $UPSD_C
- rm -f $USERS_C
- rm -f $UPSD_C
+build_server_config() {
+ mkdir -m 0755 -p "$(dirname "$UPSD_C")"
+ rm -f "$USERS_C"
+ rm -f "$UPSD_C"
rm -f /var/etc/nut/nut.conf
- echo "# Config file automatically generated from UCI config" > $UPS_C
- echo "# Config file automatically generated from UCI config" > $USERS_C
- echo "# Config file automatically generated from UCI config" > $UPSD_C
-
- local in_driver have_drivers
- config_cb() {
- if [ "$1" != "driver" ]; then
- in_driver=
- else
- echo "[$2]" >> $UPS_C
- in_driver=true
- have_drivers=true
- fi
- }
- option_cb() {
- if [ "$in_driver" = "true" ]; then
- echo " $1 = $2" >> $UPS_C
- fi
- }
-
- config_load nut_server
+ echo "# Config file automatically generated from UCI config" > "$USERS_C"
+ echo "# Config file automatically generated from UCI config" > "$UPSD_C"
config_foreach nut_user_add user
- config_foreach upsd_config upsd
config_foreach listen_address listen_address
-
+ config_foreach upsd_config upsd
echo "MODE=netserver" >>/var/etc/nut/nut.conf
- chmod 0640 $USERS_C
- chmod 0640 $UPS_C
- chmod 0640 $UPSD_C
- chmod 0640 /var/etc/nut/nut.conf
- [ -d "${statepath:-/var/run/nut}" ] || {
- mkdir -m 0750 -p "${statepath:-/var/run/nut}"
- chown $runas:$(id -gn $runas) "${statepath:-/var/run/nut}"
+ chmod 0640 "$USERS_C"
+ chmod 0640 "$UPSD_C"
+ chmod 0644 /var/etc/nut/nut.conf
+
+ [ -d "${STATEPATH}" ] || {
+ mkdir -m 0750 -p "${STATEPATH}"
}
- if [ -n "$runas" ]; then
- chown -R $runas:$(id -gn $runas) /var/etc/nut
+ if [ -n "$RUNAS" ]; then
+ chown $RUNAS:$(id -gn $RUNAS) "${STATEPATH}"
+ chgrp $(id -gn $RUNAS) "$USERS_C"
+ chgrp $(id -gn $RUNAS) "$UPSD_C"
fi
+ haveserver=1
+}
- if [ "$have_drivers" = "true" ]; then
- $DEBUG /usr/sbin/upsd ${runas:+-u $runas} $OPTIONS
- $DEBUG /usr/sbin/upsdrvctl ${runas:+-u $runas} start
- fi
+build_driver_config() {
+ local cfg="$1"
+
+ echo "[$cfg]" >>"$UPS_C"
+
+ get_write_driver_config "$cfg" driver "usbhid-ups"
+ get_write_driver_config "$cfg" port "auto"
+ get_write_driver_config "$cfg" sdorder
+ get_write_driver_config "$cfg" desc
+ get_write_driver_config "$cfg" nolock 0 1
+ get_write_driver_config "$cfg" ignorelb 0 1
+ get_write_driver_config "$cfg" mfr
+ get_write_driver_config "$cfg" model
+ get_write_driver_config "$cfg" serial
+ get_write_driver_config "$cfg" sdtime
+ get_write_driver_config "$cfg" offdelay
+ get_write_driver_config "$cfg" ondelay
+ get_write_driver_config "$cfg" pollfreq
+ get_write_driver_config "$cfg" vendor
+ get_write_driver_config "$cfg" product
+ get_write_driver_config "$cfg" bus
+ get_write_driver_config "$cfg" interruptonly 0 1
+ get_write_driver_config "$cfg" interruptsize
+ get_write_driver_config "$cfg" maxreport
+ get_write_driver_config "$cfg" vendorid
+ get_write_driver_config "$cfg" productid
+ get_write_driver_config "$cfg" community
+ get_write_driver_config "$cfg" snmp_version
+ get_write_driver_config "$cfg" snmp_retries
+ get_write_driver_config "$cfg" snmp_timeout
+ get_write_driver_config "$cfg" notransferoids 0 1
+ get_write_driver_config "$cfg" maxstartdelay
+ get_write_driver_config "$cfg" retrydelay
+ get_write_driver_config "$cfg" synchronous
+ get_write_driver_config "$cfg" other
+ get_write_driver_config "$cfg" otherflag
+
+ defoverride() {
+ local overvar="$1"
+ local defover="$2"
+ local overtype="$(echo "$overvar" | tr '.' '_')"
+
+ config_get overval "${defover}_${overtype}" value
+ [ -n "$overval" ] && echo "${defover}.${overvar} = $overval" >>"$UPS_C"
+ }
+
+ config_list_foreach "$cfg" override defoverride override
+ config_list_foreach "$cfg" default defoverride default
+
+ other() {
+ local othervar="$1"
+ local othervarflag="$2"
+
+ if [ "$othervarflag" = "otherflag" ]; then
+ config_get_bool otherval "${othervarflag}_${overtype}" value
+ [ "$otherval" = "1" ] && echo "${othervarflag}_${othervar}" >>"$UPS_C"
+ else
+ config_get otherval "${othervarflag}_${overtype}" value
+ [ -n "$otherval" ] && echo "${othervarflag}_${othervar} = $otherval" >>"$UPS_C"
+ fi
+ }
+
+ config_list_foreach "$cfg" override defoverride override
+ config_list_foreach "$cfg" default defoverride default
+ config_list_foreach "$cfg" default other other
+ config_list_foreach "$cfg" default other otherflag
+ echo "" >>$UPS_C
+ havedriver=1
+}
+
+build_global_driver_config() {
+ local cfg="$1"
+
+ # Global driver config
+ get_write_driver_config "$cfg" chroot
+ get_write_driver_config "$cfg" driverpath
+ get_write_driver_config "$cfg" maxstartdelay
+ get_write_driver_config "$cfg" maxretry
+ get_write_driver_config "$cfg" retrydelay
+ get_write_driver_config "$cfg" pollinterval
+ get_write_driver_config "$cfg" synchronous
+ config_get runas "$cfg" user "nut"
+ RUNAS="$runas"
+ upsd_runas
+
+ echo "" >>$UPS_C
}
+build_config() {
+ local RUNAS=nut
+ local STATEPATH=/var/run/nut
-nut_driver_stop() {
+ mkdir -m 0755 -p "$(dirname "$UPS_C")"
+ rm -f "$UPS_C"
+ echo "# Config file automatically generated from UCI config" > "$UPS_C"
+ chmod 0640 "$UPS_C"
+
+ config_load nut_server
+ config_foreach upsd_statepath upsd
+
+ config_foreach build_global_driver_config driver_global
+ config_foreach build_driver_config driver
+ [ -n "$RUNAS" ] && chgrp $(id -gn $RUNAS) "$UPS_C"
+
+ build_server_config
+}
+
+start_driver_instance() {
local cfg="$1"
+ local requested="$2"
local driver
+ local STATEPATH=/var/run/nut
+ local RUNAS=nut
- config_get driver "$cfg" driver
+ [ "$havedriver" != 1 ] && return
+
+ # If wanting a specific instance, only start it
+ [ "$requested" != "$cfg" ] && [ x"$requested" != x ] && return 0
+
+ mkdir -m 0755 -p "$(dirname "$UPS_C")"
+
+ [ ! -s "$UPS_C" ] && build_config
+
+ # Avoid hotplug inadvertenly restarting driver during
+ # forced shutdown
+ [ -f /var/run/killpower ] && return 0
+ [ -d /var/run/nut ] && [ -f /var/run/nut/disable-hotplug ] && return 0
- [ -r ${statepath:-/var/run/nut}/$driver-$cfg ] && /usr/sbin/upsdrvctl stop $cfg
-}
-stop_service() {
- [ -r $PID_F ] && /usr/sbin/upsd -c stop
- config_load ups
config_foreach upsd_statepath upsd
- config_foreach nut_driver_stop driver
+
+ if [ -n "$RUNAS" ]; then
+ chown $RUNAS:$(id -gn $RUNAS) "${STATEPATH}"
+ fi
+
+ config_get driver "$cfg" driver "usbhid-ups"
+ procd_open_instance "$cfg"
+ procd_set_param respawn
+ procd_set_param stderr 0
+ procd_set_param stdout 1
+ procd_set_param command /lib/nut/${driver} -D -a "$cfg" ${RUNAS:+-u $RUNAS}
+ procd_close_instance
+}
+
+start_server_instance() {
+ local RUNAS
+ build_config
+
+ [ "$haveserver" != 1 ] && return
+
+ procd_open_instance "upsd"
+ procd_set_param respawn
+ procd_set_param stderr 0
+ procd_set_param stdout 1
+ procd_set_param command /usr/sbin/upsd -D ${RUNAS:+-u $RUNAS}
+ procd_close_instance
+}
+
+start_service() {
+ local havedriver haveserver
+ local STATEPATH=/var/run/nut
+
+ # Avoid hotplug inadvertenly restarting driver during
+ # forced shutdown
+ [ -f /var/run/killpower ] && return 0
+ [ -f /var/run/nut/disable-hotplug ] && return 0
+
+ config_load nut_server
+
+ build_config
+ config_foreach start_driver_instance driver "$@"
+
+ start_server_instance "upsd"
}
reload_service() {
- upsd -c reload
+ stop
+ sleep 2
+ local havedriver haveserver
+ start
+}
+
+service_triggers() {
+ procd_add_reload_trigger "nut_server"
}
#config upsmon 'upsmon'
# option runas run-as-user
# option minsupplies 1
-# option shutdowncmd /sbin/halt
+# option shutdowncmd '/usr/sbin/nutshutdown'
# option notifycmd /path/to/cmd
# list defaultnotify SYSLOG
# option pollfreq 5
# option pollfreqalert 5
# option hostsync 15
# option deadtime 15
-# option powerdownflags /var/run/killpower
# option onlinemsg "online message"
# option onbattmsg "on battery message"
# option lowbattmsg "low battery message"
# option powervalue 1
# option username upsuser
# option password upspassword
-
# option maxage 15
# option statepath /var/run/nut
# option maxconn 1024
+# option runas nut
# NB: certificates only apply to SSL-enabled version
# option certfile /usr/local/etc/upsd.pem
--- /dev/null
+#!/bin/sh
+#
+# This is free software, licensed under the GNU General Public License v2.
+# See /LICENSE for more information.
+#
+
+. /lib/functions.sh
+
+mount -o remount,ro /overlay /overlay
+mount -o remount,ro / /
+
+stop_instance() {
+ /etc/init.d/nut-server stop "$1"
+}
+
+shutdown_instance() {
+ local cfg="$1"
+ config_get driver "$cfg" driver "usbhid-ups"
+ /lib/nut/${driver} -a "$cfg" -k
+}
+
+[ -f /var/run/killpower ] && {
+ [ -f /etc/config/nut_server ] && {
+ config_load nut_server
+
+ # Can't FSD unless drivers are stopped
+ config_foreach stop_instance driver
+ # Driver will wait 'offdelay' before shutting down
+ config_foreach shutdown_instance driver
+ # So this can happen
+ poweroff
+ # And just in case
+ sleep 120
+ # Uh-oh failed to poweroff UPS
+ reboot -f
+ } || {
+ poweroff
+ }
+} || {
+ poweroff
+}