The Marvell switches under some conditions will pass a frame to the
host with the port being the CPU port. Such frames are invalid, and
should be dropped. Not dropping them can result in a crash when
incrementing the receive statistics for an invalid port.
Reported-by: Chris Healy <cphealy@gmail.com>
Fixes: 91da11f870f0 ("net: Distributed Switch Architecture protocol support")
Signed-off-by: Andrew Lunn <andrew@lunn.ch>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
struct dsa_port *cpu_dp = dev->dsa_ptr;
struct dsa_switch_tree *dst = cpu_dp->dst;
struct dsa_switch *ds;
+ struct dsa_port *slave_port;
if (device < 0 || device >= DSA_MAX_SWITCHES)
return NULL;
if (port < 0 || port >= ds->num_ports)
return NULL;
- return ds->ports[port].slave;
+ slave_port = &ds->ports[port];
+
+ if (unlikely(slave_port->type != DSA_PORT_TYPE_USER))
+ return NULL;
+
+ return slave_port->slave;
}
/* port.c */