temperature is reported in milli-Celsius
Signed-off-by: Peter Meerwald <pmeerw@pmeerw.net>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
return -EINVAL;
}
case IIO_CHAN_INFO_SCALE:
- *val = 0;
- *val2 = 1000;
+ switch (chan->type) {
+ case IIO_MAGN:
+ *val = 0;
+ *val2 = 1000;
+ return IIO_VAL_INT_PLUS_MICRO;
+ case IIO_TEMP:
+ *val = 1000;
+ return IIO_VAL_INT;
+ default:
+ return -EINVAL;
+ }
return IIO_VAL_INT_PLUS_MICRO;
case IIO_CHAN_INFO_SAMP_FREQ:
i = data->ctrl_reg1 >> MAG3110_CTRL_DR_SHIFT;
MAG3110_CHANNEL(Z, 2),
{
.type = IIO_TEMP,
- .info_mask_separate = BIT(IIO_CHAN_INFO_RAW),
+ .info_mask_separate = BIT(IIO_CHAN_INFO_RAW) |
+ BIT(IIO_CHAN_INFO_SCALE),
.scan_index = 3,
.scan_type = {
.sign = 's',