net: mvpp2: use only one rx queue per port per CPU
authorMaxime Chevallier <maxime.chevallier@bootlin.com>
Thu, 12 Jul 2018 11:54:16 +0000 (13:54 +0200)
committerDavid S. Miller <davem@davemloft.net>
Fri, 13 Jul 2018 00:30:48 +0000 (17:30 -0700)
The number of receive queue per port is :
 - MVPP2_DEFAULT_RXQ if in single queue mode
 - MVPP2_DEFAULT_RXQ * num_possible_cpus if in multi queue mode

with MVPP2_DEFAULT_RXQ = 4.

However, we don't use the extra rx queues at the moment, we really only
need one per port per CPU, until some more advanced classification rules
are implemented.

Suggested-by: Stefan Chulski <stefanc@marvell.com>
Signed-off-by: Maxime Chevallier <maxime.chevallier@bootlin.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
drivers/net/ethernet/marvell/mvpp2/mvpp2.h

index 5ef5b99a19351c2d664b5946093ebc6c8b611b76..dee5231b00730201e48828c491d2ff1b806c2502 100644 (file)
 #define MVPP2_MAX_SKB_DESCS            (MVPP2_MAX_TSO_SEGS * 2 + MAX_SKB_FRAGS)
 
 /* Dfault number of RXQs in use */
-#define MVPP2_DEFAULT_RXQ              4
+#define MVPP2_DEFAULT_RXQ              1
 
 /* Max number of Rx descriptors */
 #define MVPP2_MAX_RXD_MAX              1024