Some vendor-specific initialization flow may set its own auto-hibernate
timer. In this case, do not overwrite timer value as "default value" in
ufshcd_init().
Signed-off-by: Stanley Chu <stanley.chu@mediatek.com>
Reviewed-by: Alim Akhtar <alim.akhtar@samsung.com>
Reviewed-by: Avri Altman <Avri.Altman@wdc.com>
Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
UIC_LINK_HIBERN8_STATE);
/* Set the default auto-hiberate idle timer value to 150 ms */
- if (ufshcd_is_auto_hibern8_supported(hba)) {
+ if (ufshcd_is_auto_hibern8_supported(hba) && !hba->ahit) {
hba->ahit = FIELD_PREP(UFSHCI_AHIBERN8_TIMER_MASK, 150) |
FIELD_PREP(UFSHCI_AHIBERN8_SCALE_MASK, 3);
}