We need to flush the msgr workqueue during mon_client shutdown to
ensure that any work affecting our embedded ceph_connection is
finished so that we can be safely destroyed.
Previously, we were flushing the work queue after osd_client
shutdown and before mon_client shutdown to ensure that any osd
connection refs to authorizers are flushed. Remove the redundant
flush, and document in the comment that the mon_client flush is
needed to cover that case as well.
Signed-off-by: Sage Weil <sage@inktank.com>
Reviewed-by: Alex Elder <elder@inktank.com>
/* unmount */
ceph_osdc_stop(&client->osdc);
- /*
- * make sure osd connections close out before destroying the
- * auth module, which is needed to free those connections'
- * ceph_authorizers.
- */
- ceph_msgr_flush();
-
ceph_monc_stop(&client->monc);
ceph_debugfs_client_cleanup(client);
mutex_unlock(&monc->mutex);
+ /*
+ * flush msgr queue before we destroy ourselves to ensure that:
+ * - any work that references our embedded con is finished.
+ * - any osd_client or other work that may reference an authorizer
+ * finishes before we shut down the auth subsystem.
+ */
+ ceph_msgr_flush();
+
ceph_auth_destroy(monc->auth);
ceph_msg_put(monc->m_auth);