The atmel-mci driver sometimes fails data transfers like this:
mmcblk0: error -5 transferring data
end_request: I/O error, dev mmcblk0, sector
2749769
end_request: I/O error, dev mmcblk0, sector
2749777
It turns out that this might be caused by the BLKR register (which
contains the block size and the number of blocks being transfered) being
initialized too late. This patch moves the initialization of BLKR so
that it contains the correct value before the block transfer command is
sent.
This error is difficult to reproduce, but if you insert a long delay
(mdelay(10) or thereabouts) between the calls to atmci_start_command()
and atmci_submit_data(), all transfers seem to fail without this patch,
while I haven't seen any failures with this patch.
Reported-by: Hein_Tibosch <hein_tibosch@yahoo.es>
Signed-off-by: Haavard Skinnemoen <haavard.skinnemoen@atmel.com>
Signed-off-by: Pierre Ossman <drzeus@drzeus.cx>
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
host->sg = NULL;
host->data = data;
- mci_writel(host, BLKR, MCI_BCNT(data->blocks)
- | MCI_BLKLEN(data->blksz));
dev_vdbg(&mmc->class_dev, "BLKR=0x%08x\n",
MCI_BCNT(data->blocks) | MCI_BLKLEN(data->blksz));
if (data->blocks > 1 && data->blksz & 3)
goto fail;
atmci_set_timeout(host, data);
+
+ /* Must set block count/size before sending command */
+ mci_writel(host, BLKR, MCI_BCNT(data->blocks)
+ | MCI_BLKLEN(data->blksz));
}
iflags = MCI_CMDRDY;