So far we effectively clear the BMCR register. Some PHY's can deal
with this (e.g. because they reset BMCR to a default as part of a
soft-reset) whilst on others this causes issues because e.g. the
autoneg bit is cleared. Marvell is an example, see also thread [0].
So let's be a little bit more gentle and leave all bits we're not
interested in as-is. This change is needed for PHY drivers to
properly deal with the original patch.
[0] https://marc.info/?t=
155264050700001&r=1&w=2
Fixes: 6e2d85ec0559 ("net: phy: Stop with excessive soft reset")
Tested-by: Phil Reid <preid@electromag.com.au>
Tested-by: liweihang <liweihang@hisilicon.com>
Signed-off-by: Heiner Kallweit <hkallweit1@gmail.com>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
{
int ret;
- ret = phy_write(phydev, MII_BMCR, BMCR_RESET);
+ ret = phy_set_bits(phydev, MII_BMCR, BMCR_RESET);
if (ret < 0)
return ret;