After an error interrupt setting cmd->err, I see another interrupt that
the data engine is empty which clears cmd->err before being processed.
So, clear cmd->err at the beginning of a transfer only to handle these
consecutive interrupts.
Signed-off-by: Wolfram Sang <w.sang@pengutronix.de>
return -EINVAL;
init_completion(&i2c->cmd_complete);
+ i2c->cmd_err = 0;
flags = stop ? MXS_I2C_CTRL0_POST_SEND_STOP : 0;
MXS_I2C_CTRL1_SLAVE_STOP_IRQ | MXS_I2C_CTRL1_SLAVE_IRQ))
/* MXS_I2C_CTRL1_OVERSIZE_XFER_TERM_IRQ is only for slaves */
i2c->cmd_err = -EIO;
- else
- i2c->cmd_err = 0;
is_last_cmd = (readl(i2c->regs + MXS_I2C_QUEUESTAT) &
MXS_I2C_QUEUESTAT_WRITE_QUEUE_CNT_MASK) == 0;