In my setup data transfer stalls when there's data transmission during
scan. After some testing I found out that using background scan
when connected to makes the problem go away. This is more like
a workaround than a proper fix, but as the stall is so severe the
workaround is justified.
With a dual band card this increases scan time when connected from
1.9s to 4.4s. When not connected the scan time is not affected and
is the same 1.9s.
Signed-off-by: Kalle Valo <kvalo@qca.qualcomm.com>
{
struct ath6kl *ar = (struct ath6kl *)ath6kl_priv(ndev);
int ret = 0;
- u32 force_fg_scan = 0;
if (!ath6kl_cfg80211_ready(ar))
return -EIO;
request->ssids[i].ssid);
}
- if (test_bit(CONNECTED, &ar->flag))
- force_fg_scan = 1;
-
- if (ath6kl_wmi_startscan_cmd(ar->wmi, WMI_LONG_SCAN, force_fg_scan,
+ if (ath6kl_wmi_startscan_cmd(ar->wmi, WMI_LONG_SCAN, 0,
false, 0, 0, 0, NULL) != 0) {
ath6kl_err("wmi_startscan_cmd failed\n");
ret = -EIO;