kirkwood: do not expose status LED to user config by default
authorAdrian Schmutzler <freifunk@adrianschmutzler.de>
Fri, 21 Feb 2020 20:09:25 +0000 (21:09 +0100)
committerAdrian Schmutzler <freifunk@adrianschmutzler.de>
Sat, 22 Feb 2020 13:25:52 +0000 (14:25 +0100)
So far, the state of status LEDs is set up in 01_leds for many devices
in kirkwood target. As those LEDs are also controlled by diag.sh,
exposing them to the user via uci config by default seems not helpful
and might even have confusing results for the user.

Thus, remove the ucidef_set_led_default setup for power/status LED, but
do not touch the rest where user control is actually a feature.

Signed-off-by: Adrian Schmutzler <freifunk@adrianschmutzler.de>
target/linux/kirkwood/base-files/etc/board.d/01_leds

index 504be16480de38d4d44b2fd56397fb2752a065db..bba845eae58d242793270e1df66015fa91b32d42 100755 (executable)
@@ -10,41 +10,18 @@ board_config_update
 board=$(board_name)
 
 case "$board" in
-"cloudengines,pogoe02")
-       ucidef_set_led_default "health" "health" "pogo_e02:green:health" "1"
-       ucidef_set_led_default "fault" "fault" "pogo_e02:orange:fault" "1"
-       ;;
 "iom,ix2-200")
        ucidef_set_led_timer "health" "health" "status:white:rebuild_led" "200" "800"
        ;;
-"linksys,audi")
-       ucidef_set_led_default "power" "power" "audi:green:power" "1"
-       ;;
 "linksys,viper")
-       ucidef_set_led_default "health" "health" "viper:white:health" "1"
        ucidef_set_led_default "pulse" "pulse" "viper:white:pulse" "1"
        ;;
-"raidsonic,ib-nas62x0")
-       ucidef_set_led_default "health" "health" "ib62x0:green:os" "1"
-       ucidef_set_led_default "fault" "fault" "ib62x0:red:os" "1"
-       ;;
-"seagate,dockstar")
-       ucidef_set_led_default "health" "health" "status:green:health" "1"
-       ucidef_set_led_default "fault" "fault" "status:orange:fault" "1"
-       ;;
-"seagate,goflexhome"|\
-"seagate,goflexnet")
-       ucidef_set_led_default "health" "health" "status:green:health" "1"
-       ucidef_set_led_default "fault" "fault" "status:orange:fault" "0"
-       ;;
 "zyxel,nsa310b")
-       ucidef_set_led_default "health" "health" "nsa310:green:sys" "1"
        ucidef_set_led_usbhost "usb" "USB" "nsa310:green:usb"
        ucidef_set_led_ataport "hdd" "HDD" "nsa310:green:hdd" "1"
        ucidef_set_led_ataport "esata" "eSata" "nsa310:green:esata" "2"
        ;;
 "zyxel,nsa325")
-       ucidef_set_led_default "health" "health" "nsa325:green:sys" "1"
        ucidef_set_led_usbhost "usb" "USB" "nsa325:green:usb"
        ucidef_set_led_ataport "hdd1" "HDD1" "nsa325:green:hdd1" "1"
        ucidef_set_led_ataport "hdd2" "HDD2" "nsa325:green:hdd2" "2"