If the devicetree specifies a serial port as a stdout device, then the
kernel can use it as the default console if nothing else was selected on
the command line. For any serial port that uses the uart_add_one_port()
feature, the uart_add_one_port() has all the information needed to
automatically enable the console device, which is what this patch does.
With this change applied, a device tree platform can be booted without
any console= parameters on the command line and the kernel will still be
able to determine its console.
Tested on QEMU Versatile model and i.MX
Signed-off-by: Grant Likely <grant.likely@linaro.org>
Tested-by: Sascha Hauer <s.hauer@pengutronix.de>
#include <linux/slab.h>
#include <linux/init.h>
#include <linux/console.h>
+#include <linux/of.h>
#include <linux/proc_fs.h>
#include <linux/seq_file.h>
#include <linux/device.h>
spin_lock_init(&uport->lock);
lockdep_set_class(&uport->lock, &port_lock_key);
}
+ if (uport->cons && uport->dev)
+ of_console_check(uport->dev->of_node, uport->cons->name, uport->line);
uart_configure_port(drv, state, uport);