The PTP egress timestamp N must be captured from register PTPEGR_TS[n],
where n = 2 * PORT + TSREG. There are 10 PTPEGR_TS registers, 2 per
port. We are only using TSREG=0.
As opposed to the management slots, which are 4 in number
(SJA1105_NUM_PORTS, minus the CPU port). Any management frame (which
includes PTP frames) can be sent to any non-CPU port through any
management slot. When the CPU port is not the last port (#4), there will
be a mismatch between the slot and the port number.
Luckily, the only mainline occurrence with this switch
(arch/arm/boot/dts/ls1021a-tsn.dts) does have the CPU port as #4, so the
issue did not manifest itself thus far.
Fixes: 47ed985e97f5 ("net: dsa: sja1105: Add logic for TX timestamping")
Signed-off-by: Vladimir Oltean <olteanv@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
if (!clone)
goto out;
- sja1105_ptp_txtstamp_skb(ds, slot, clone);
+ sja1105_ptp_txtstamp_skb(ds, port, clone);
out:
mutex_unlock(&priv->mgmt_lock);
ptp_data->clock = NULL;
}
-void sja1105_ptp_txtstamp_skb(struct dsa_switch *ds, int slot,
+void sja1105_ptp_txtstamp_skb(struct dsa_switch *ds, int port,
struct sk_buff *skb)
{
struct sja1105_private *priv = ds->priv;
goto out;
}
- rc = sja1105_ptpegr_ts_poll(ds, slot, &ts);
+ rc = sja1105_ptpegr_ts_poll(ds, port, &ts);
if (rc < 0) {
dev_err(ds->dev, "timed out polling for tstamp\n");
kfree_skb(skb);