kernel: ip17xx: use pr_warn instead of pr_warning
authorFelix Fietkau <nbd@nbd.name>
Sat, 24 Oct 2020 16:11:15 +0000 (18:11 +0200)
committerFelix Fietkau <nbd@nbd.name>
Fri, 13 Nov 2020 12:16:31 +0000 (13:16 +0100)
Fixes build with newer kernels

Signed-off-by: Felix Fietkau <nbd@nbd.name>
target/linux/generic/files/drivers/net/phy/ip17xx.c

index 85a9617a5dad5922a59ebe16ace22b579028d7e6..88bdc29cb7eee7ea17b35855c36df9e3a154a8c7 100644 (file)
@@ -329,7 +329,7 @@ static int ip_phy_read(struct ip17xx_state *state, int port, int reg)
 {
        int val = mdiobus_read(state->mii_bus, port, reg);
        if (val < 0)
-               pr_warning("IP17xx: Unable to get MII register %d,%d: error %d\n", port, reg, -val);
+               pr_warn("IP17xx: Unable to get MII register %d,%d: error %d\n", port, reg, -val);
 #ifdef DUMP_MII_IO
        else
                pr_debug("IP17xx: Read MII(%d,%d) -> %04x\n", port, reg, val);
@@ -346,7 +346,7 @@ static int ip_phy_write(struct ip17xx_state *state, int port, int reg, u16 val)
 #endif
        err = mdiobus_write(state->mii_bus, port, reg, val);
        if (err < 0)
-               pr_warning("IP17xx: Unable to write MII register %d,%d: error %d\n", port, reg, -err);
+               pr_warn("IP17xx: Unable to write MII register %d,%d: error %d\n", port, reg, -err);
        return err;
 }
 
@@ -451,7 +451,7 @@ static int get_model(struct ip17xx_state *state)
                        }
                }
        } else {
-               pr_warning("IP17xx: Found an unknown IC+ switch with model number %02x, revision %X.\n", model_no, rev_no);
+               pr_warn("IP17xx: Found an unknown IC+ switch with model number %02x, revision %X.\n", model_no, rev_no);
                return -EPERM;
        }
        return 0;