[PATCH] ppc32: Simplified load string emulation error checking
authorKumar Gala <galak@freescale.com>
Sat, 28 May 2005 22:52:13 +0000 (15:52 -0700)
committerLinus Torvalds <torvalds@ppc970.osdl.org>
Sat, 28 May 2005 23:46:16 +0000 (16:46 -0700)
The error checking for emulation of load string instructions was overly
generous and would cause certain valid forms of the instructions to be
treated as illegal.  We drop the range checking since the architecture
allows this to be boundedly undefined.  Tests on CPUs that support these
instructions appear not do cause illegal instruction traps on range errors
and just allow the execution to occur.

Thanks to Kim Phillips for debugging this and figuring out what real HW was
doing.

Signed-off-by: Kumar Gala <kumar.gala@freescale.com>
Signed-off-by: Andrew Morton <akpm@osdl.org>
Signed-off-by: Linus Torvalds <torvalds@osdl.org>
arch/ppc/kernel/traps.c

index f8e7e324a17396fc81e64a3afbcc2cb77eaa6702..c65731e8bc657cb2edbcec90b8050ef813846803 100644 (file)
@@ -408,12 +408,7 @@ static int emulate_string_inst(struct pt_regs *regs, u32 instword)
 
        /* Early out if we are an invalid form of lswx */
        if ((instword & INST_STRING_MASK) == INST_LSWX)
-               if ((rA >= rT) || (NB_RB >= rT) || (rT == rA) || (rT == NB_RB))
-                       return -EINVAL;
-
-       /* Early out if we are an invalid form of lswi */
-       if ((instword & INST_STRING_MASK) == INST_LSWI)
-               if ((rA >= rT) || (rT == rA))
+               if ((rT == rA) || (rT == NB_RB))
                        return -EINVAL;
 
        EA = (rA == 0) ? 0 : regs->gpr[rA];