Add additional PWM fan cooling step and enable fan on BPi-R4.
Suggested-by: Frank Wunderlich <frank-w@public-files.de>
Signed-off-by: Daniel Golle <daniel@makrotopia.org>
status = "okay";
};
+&pwm {
+ status = "okay";
+};
+
+&fan {
+ pwms = <&pwm 0 50000>;
+ status = "okay";
+};
+
&ssusb1 {
status = "okay";
};
fan: pwm-fan {
compatible = "pwm-fan";
- /* cooling level (0, 1, 2) : (0% duty, 50% duty, 100% duty) */
- cooling-levels = <0 128 255>;
+ /* cooling level (0, 1, 2, 3) : (0% duty, 30% duty, 50% duty, 100% duty) */
+ cooling-levels = <0 80 128 255>;
#cooling-cells = <2>;
#thermal-sensor-cells = <1>;
status = "disabled";