[PATCH] sil24: add sil24_restart_controller
authorTejun Heo <htejun@gmail.com>
Fri, 18 Nov 2005 05:09:05 +0000 (14:09 +0900)
committerJeff Garzik <jgarzik@pobox.com>
Fri, 18 Nov 2005 18:11:39 +0000 (13:11 -0500)
When an error condition is raised by device via D2H FIS or SDB.  sil24
controller should be restarted by setting PORT_CS_INIT and waiting
until PORT_CS_RDY is asserted instead of resetting the controller.
This patch implements sil24_restart_controller for those cases.  This
patch also makes sure that PORT_CS_RDY is asserted on
sil24_reset_controller completion.

Signed-off-by: Tejun Heo <htejun@gmail.com>
--

Jeff, delay is reduced to 1us and cnt increased to 10k.  My sil3124
turns on PORT_CS_RDY on the second iteration even without any delay.
I think 10k * 1us should be more than enough.

I tried to convert both restart and reset to use msleep's with work
queue, but if we do that, host_set lock should be released after
initiating restart or reset, leading to race condition among
reset/restart, other interrupts and timeout.  Implementing
synchronization among those in low-level driver doesn't seem right.
Well, reduced timeout should work for the time being.

Thanks.
Signed-off-by: Jeff Garzik <jgarzik@pobox.com>
drivers/scsi/sata_sil24.c

index cb1933a3bd55e03ca88ccfe9e5e6af74dd9a07e6..a6836a07a9eb4ca0a8cf82aae373130aa1007d34 100644 (file)
@@ -486,6 +486,31 @@ static void sil24_irq_clear(struct ata_port *ap)
        /* unused */
 }
 
+static int __sil24_restart_controller(void __iomem *port)
+{
+       u32 tmp;
+       int cnt;
+
+       writel(PORT_CS_INIT, port + PORT_CTRL_STAT);
+
+       /* Max ~10ms */
+       for (cnt = 0; cnt < 10000; cnt++) {
+               tmp = readl(port + PORT_CTRL_STAT);
+               if (tmp & PORT_CS_RDY)
+                       return 0;
+               udelay(1);
+       }
+
+       return -1;
+}
+
+static void sil24_restart_controller(struct ata_port *ap)
+{
+       if (__sil24_restart_controller((void __iomem *)ap->ioaddr.cmd_addr))
+               printk(KERN_ERR DRV_NAME
+                      " ata%u: failed to restart controller\n", ap->id);
+}
+
 static int __sil24_reset_controller(void __iomem *port)
 {
        int cnt;
@@ -505,7 +530,11 @@ static int __sil24_reset_controller(void __iomem *port)
 
        if (tmp & PORT_CS_DEV_RST)
                return -1;
-       return 0;
+
+       if (tmp & PORT_CS_RDY)
+               return 0;
+
+       return __sil24_restart_controller(port);
 }
 
 static void sil24_reset_controller(struct ata_port *ap)
@@ -577,6 +606,7 @@ static void sil24_error_intr(struct ata_port *ap, u32 slot_stat)
                 */
                sil24_update_tf(ap);
                err_mask = ac_err_mask(pp->tf.command);
+               sil24_restart_controller(ap);
        } else {
                /*
                 * Other errors.  libata currently doesn't have any
@@ -584,12 +614,11 @@ static void sil24_error_intr(struct ata_port *ap, u32 slot_stat)
                 * ATA_ERR.
                 */
                err_mask = AC_ERR_OTHER;
+               sil24_reset_controller(ap);
        }
 
        if (qc)
                ata_qc_complete(qc, err_mask);
-
-       sil24_reset_controller(ap);
 }
 
 static inline void sil24_host_intr(struct ata_port *ap)