Fix: Raid-6 was not trying to correct a read-error when in
singly-degraded state and was instead dropping one more device, going to
doubly-degraded state. This patch fixes this behaviour.
Tested-by: Janos Haar <janos.haar@netcenter.hu>
Signed-off-by: Gabriele A. Trombetti <g.trombetti.lkrnl1213@logicschema.com>
Reported-by: Janos Haar <janos.haar@netcenter.hu>
Signed-off-by: NeilBrown <neilb@suse.de>
Cc: stable@kernel.org
clear_bit(R5_UPTODATE, &sh->dev[i].flags);
atomic_inc(&rdev->read_errors);
- if (conf->mddev->degraded)
+ if (conf->mddev->degraded >= conf->max_degraded)
printk_rl(KERN_WARNING
"md/raid:%s: read error not correctable "
"(sector %llu on %s).\n",