drm/i915: Ignore long hpds on eDP ports
authorVille Syrjälä <ville.syrjala@linux.intel.com>
Thu, 16 Oct 2014 17:46:10 +0000 (20:46 +0300)
committerJani Nikula <jani.nikula@intel.com>
Mon, 27 Oct 2014 11:37:13 +0000 (13:37 +0200)
Turning vdd on/off can generate a long hpd pulse on eDP ports. In order
to handle hpd we would need to turn on vdd to perform aux transfers.
This would lead to an endless cycle of
"vdd off -> long hpd -> vdd on -> detect -> vdd off -> ..."

So ignore long hpd pulses on eDP ports. eDP panels should be physically
tied to the machine anyway so they should not actually disappear and
thus don't need long hpd handling. Short hpds are still needed for link
re-train and whatnot so we can't just turn off the hpd interrupt
entirely for eDP ports. Perhaps we could turn it off whenever the panel
is disabled, but just ignoring the long hpd seems sufficient.

Signed-off-by: Ville Syrjälä <ville.syrjala@linux.intel.com>
Cc: stable@vger.kernel.org
Reviewed-by: Dave Airlie <airlied@redhat.com>
Reviewed-by: Todd Previte <tprevite@gmail.com>
Signed-off-by: Jani Nikula <jani.nikula@intel.com>
drivers/gpu/drm/i915/intel_dp.c

index f9c5f17af9d80b348d477be3ccf10fe608352fbe..464d8ad9bb71868994afa79100be59a9779f3f3d 100644 (file)
@@ -4498,6 +4498,18 @@ intel_dp_hpd_pulse(struct intel_digital_port *intel_dig_port, bool long_hpd)
        if (intel_dig_port->base.type != INTEL_OUTPUT_EDP)
                intel_dig_port->base.type = INTEL_OUTPUT_DISPLAYPORT;
 
+       if (long_hpd && intel_dig_port->base.type == INTEL_OUTPUT_EDP) {
+               /*
+                * vdd off can generate a long pulse on eDP which
+                * would require vdd on to handle it, and thus we
+                * would end up in an endless cycle of
+                * "vdd off -> long hpd -> vdd on -> detect -> vdd off -> ..."
+                */
+               DRM_DEBUG_KMS("ignoring long hpd on eDP port %c\n",
+                             port_name(intel_dig_port->port));
+               return false;
+       }
+
        DRM_DEBUG_KMS("got hpd irq on port %c - %s\n",
                      port_name(intel_dig_port->port),
                      long_hpd ? "long" : "short");