from commit
3ce909914a12647bec52bcee0a162dd6d158a4f6
The lldpd man page says that "configure lldp tx-interval" can
specify an interval value in milliseconds by appending a "ms" suffix to
the figure. Thus mandating string handling, and not integer comparison.
Tested on 22.03.5
Signed-off-by: Paul Donald <newtwen@gmail.com>
[ -n "$lldp_agenttype" ] && echo "configure lldp agent-type $lldp_agenttype" >> "$LLDPD_CONF"
[ -n "$lldp_portidsubtype" ] && echo "configure lldp portidsubtype $lldp_portidsubtype" >> "$LLDPD_CONF"
[ -n "$lldp_platform" ] && echo "configure system platform" "\"$lldp_platform\"" >> "$LLDPD_CONF"
- [ $lldp_tx_interval -gt 0 ] && echo "configure lldp tx-interval $lldp_tx_interval" >> "$LLDPD_CONF"
+ [ -n $lldp_tx_interval ] && echo "configure lldp tx-interval $lldp_tx_interval" >> "$LLDPD_CONF"
[ $lldp_tx_hold -gt 0 ] && echo "configure lldp tx-hold $lldp_tx_hold" >> "$LLDPD_CONF"
# Since lldpd's sysconfdir is /tmp, we'll symlink /etc/lldpd.d to /tmp/$LLDPD_CONFS_DIR