[ALSA] hda-codec - Fix model for HP dc7600
authorTakashi Iwai <tiwai@suse.de>
Fri, 26 May 2006 12:58:29 +0000 (14:58 +0200)
committerJaroslav Kysela <perex@suse.cz>
Thu, 22 Jun 2006 19:34:01 +0000 (21:34 +0200)
Changed the assigned model for HP dc7600 with ALC260 codec
to match better with the actual I/O assignment.
Patch taken from ALSA bug#2157.

Signed-off-by: Takashi Iwai <tiwai@suse.de>
sound/pci/hda/patch_realtek.c

index ceb103b93b081852a0da6759d508a1bfea9d05fc..98b9f16c26ffa633d016294e1c47f63f073d3408 100644 (file)
@@ -3834,7 +3834,7 @@ static struct hda_board_config alc260_cfg_tbl[] = {
        { .modelname = "hp", .config = ALC260_HP },
        { .pci_subvendor = 0x103c, .pci_subdevice = 0x3010, .config = ALC260_HP },
        { .pci_subvendor = 0x103c, .pci_subdevice = 0x3011, .config = ALC260_HP },
-       { .pci_subvendor = 0x103c, .pci_subdevice = 0x3012, .config = ALC260_HP },
+       { .pci_subvendor = 0x103c, .pci_subdevice = 0x3012, .config = ALC260_HP_3013 },
        { .pci_subvendor = 0x103c, .pci_subdevice = 0x3013, .config = ALC260_HP_3013 },
        { .pci_subvendor = 0x103c, .pci_subdevice = 0x3014, .config = ALC260_HP },
        { .pci_subvendor = 0x103c, .pci_subdevice = 0x3015, .config = ALC260_HP },