* TSC module need ADC to get the measure value. So
* before config TSC, we should initialize ADC module.
*/
-static void imx6ul_adc_init(struct imx6ul_tsc *tsc)
+static int imx6ul_adc_init(struct imx6ul_tsc *tsc)
{
int adc_hc = 0;
int adc_gc;
timeout = wait_for_completion_timeout
(&tsc->completion, ADC_TIMEOUT);
- if (timeout == 0)
+ if (timeout == 0) {
dev_err(tsc->dev, "Timeout for adc calibration\n");
+ return -ETIMEDOUT;
+ }
adc_gs = readl(tsc->adc_regs + REG_ADC_GS);
- if (adc_gs & ADC_CALF)
+ if (adc_gs & ADC_CALF) {
dev_err(tsc->dev, "ADC calibration failed\n");
+ return -EINVAL;
+ }
/* TSC need the ADC work in hardware trigger */
adc_cfg = readl(tsc->adc_regs + REG_ADC_CFG);
adc_cfg |= ADC_HARDWARE_TRIGGER;
writel(adc_cfg, tsc->adc_regs + REG_ADC_CFG);
+
+ return 0;
}
/*
writel(start, tsc->tsc_regs + REG_TSC_FLOW_CONTROL);
}
-static void imx6ul_tsc_init(struct imx6ul_tsc *tsc)
+static int imx6ul_tsc_init(struct imx6ul_tsc *tsc)
{
- imx6ul_adc_init(tsc);
+ int err;
+
+ err = imx6ul_adc_init(tsc);
+ if (err)
+ return err;
imx6ul_tsc_channel_config(tsc);
imx6ul_tsc_set(tsc);
+
+ return 0;
}
static void imx6ul_tsc_disable(struct imx6ul_tsc *tsc)
return err;
}
- imx6ul_tsc_init(tsc);
-
- return 0;
+ return imx6ul_tsc_init(tsc);
}
static void imx6ul_tsc_close(struct input_dev *input_dev)
goto out;
}
- imx6ul_tsc_init(tsc);
+ retval = imx6ul_tsc_init(tsc);
}
out: