net: phylink: Fix flow control resolution
authorStefan Chulski <stefanc@marvell.com>
Thu, 5 Sep 2019 16:46:18 +0000 (19:46 +0300)
committerDavid S. Miller <davem@davemloft.net>
Sat, 7 Sep 2019 15:26:13 +0000 (17:26 +0200)
Regarding to IEEE 802.3-2015 standard section 2
28B.3 Priority resolution - Table 28-3 - Pause resolution

In case of Local device Pause=1 AsymDir=0, Link partner
Pause=1 AsymDir=1, Local device resolution should be enable PAUSE
transmit, disable PAUSE receive.
And in case of Local device Pause=1 AsymDir=1, Link partner
Pause=1 AsymDir=0, Local device resolution should be enable PAUSE
receive, disable PAUSE transmit.

Fixes: 9525ae83959b ("phylink: add phylink infrastructure")
Signed-off-by: Stefan Chulski <stefanc@marvell.com>
Reported-by: Shaul Ben-Mayor <shaulb@marvell.com>
Acked-by: Russell King <rmk+kernel@armlinux.org.uk>
Signed-off-by: David S. Miller <davem@davemloft.net>
drivers/net/phy/phylink.c

index a45c5de96ab1c9688c0ed1eaa99f60fef3294230..a5a57ca94c1ac541092867b685fe7d616218f96b 100644 (file)
@@ -376,8 +376,8 @@ static void phylink_get_fixed_state(struct phylink *pl, struct phylink_link_stat
  *  Local device  Link partner
  *  Pause AsymDir Pause AsymDir Result
  *    1     X       1     X     TX+RX
- *    0     1       1     1     RX
- *    1     1       0     1     TX
+ *    0     1       1     1     TX
+ *    1     1       0     1     RX
  */
 static void phylink_resolve_flow(struct phylink *pl,
                                 struct phylink_link_state *state)
@@ -398,7 +398,7 @@ static void phylink_resolve_flow(struct phylink *pl,
                        new_pause = MLO_PAUSE_TX | MLO_PAUSE_RX;
                else if (pause & MLO_PAUSE_ASYM)
                        new_pause = state->pause & MLO_PAUSE_SYM ?
-                                MLO_PAUSE_RX : MLO_PAUSE_TX;
+                                MLO_PAUSE_TX : MLO_PAUSE_RX;
        } else {
                new_pause = pl->link_config.pause & MLO_PAUSE_TXRX_MASK;
        }