[PATCH] sched: mc/smt power savings sched policy
authorSiddha, Suresh B <suresh.b.siddha@intel.com>
Tue, 27 Jun 2006 09:54:42 +0000 (02:54 -0700)
committerLinus Torvalds <torvalds@g5.osdl.org>
Wed, 28 Jun 2006 00:32:45 +0000 (17:32 -0700)
sysfs entries 'sched_mc_power_savings' and 'sched_smt_power_savings' in
/sys/devices/system/cpu/ control the MC/SMT power savings policy for the
scheduler.

Based on the values (1-enable, 0-disable) for these controls, sched groups
cpu power will be determined for different domains.  When power savings
policy is enabled and under light load conditions, scheduler will minimize
the physical packages/cpu cores carrying the load and thus conserving
power(with a perf impact based on the workload characteristics...  see OLS
2005 CMP kernel scheduler paper for more details..)

Signed-off-by: Suresh Siddha <suresh.b.siddha@intel.com>
Cc: Ingo Molnar <mingo@elte.hu>
Cc: Nick Piggin <nickpiggin@yahoo.com.au>
Cc: Con Kolivas <kernel@kolivas.org>
Cc: "Chen, Kenneth W" <kenneth.w.chen@intel.com>
Cc: "David S. Miller" <davem@davemloft.net>
Signed-off-by: Andrew Morton <akpm@osdl.org>
Signed-off-by: Linus Torvalds <torvalds@osdl.org>
arch/i386/kernel/smpboot.c
arch/x86_64/kernel/smpboot.c
drivers/base/cpu.c
include/asm-i386/topology.h
include/asm-ia64/topology.h
include/asm-powerpc/topology.h
include/asm-sparc64/topology.h
include/asm-x86_64/topology.h
include/linux/sched.h
include/linux/topology.h
kernel/sched.c

index ab5275beddf78573f13130191527e77daf781461..89e7315e539c49a5f8f19a3479ae21774075a374 100644 (file)
@@ -448,10 +448,12 @@ cpumask_t cpu_coregroup_map(int cpu)
        struct cpuinfo_x86 *c = cpu_data + cpu;
        /*
         * For perf, we return last level cache shared map.
-        * TBD: when power saving sched policy is added, we will return
-        *      cpu_core_map when power saving policy is enabled
+        * And for power savings, we return cpu_core_map
         */
-       return c->llc_shared_map;
+       if (sched_mc_power_savings || sched_smt_power_savings)
+               return cpu_core_map[cpu];
+       else
+               return c->llc_shared_map;
 }
 
 /* representing cpus for which sibling maps can be computed */
index 4e9755179ecf57022bcb8e4e6adaa76d62612010..540c0ccbcccc8953c95ee6b6c2baf5ad11e44aaf 100644 (file)
@@ -455,10 +455,12 @@ cpumask_t cpu_coregroup_map(int cpu)
        struct cpuinfo_x86 *c = cpu_data + cpu;
        /*
         * For perf, we return last level cache shared map.
-        * TBD: when power saving sched policy is added, we will return
-        *      cpu_core_map when power saving policy is enabled
+        * And for power savings, we return cpu_core_map
         */
-       return c->llc_shared_map;
+       if (sched_mc_power_savings || sched_smt_power_savings)
+               return cpu_core_map[cpu];
+       else
+               return c->llc_shared_map;
 }
 
 /* representing cpus for which sibling maps can be computed */
index 3972d8ac9786872bfc2890152efbc52dd196bb9a..4bef76a2f3f2a7611ff0dcbca79c8d774d7a7255 100644 (file)
@@ -143,5 +143,13 @@ EXPORT_SYMBOL_GPL(get_cpu_sysdev);
 
 int __init cpu_dev_init(void)
 {
-       return sysdev_class_register(&cpu_sysdev_class);
+       int err;
+
+       err = sysdev_class_register(&cpu_sysdev_class);
+#if defined(CONFIG_SCHED_MC) || defined(CONFIG_SCHED_SMT)
+       if (!err)
+               err = sched_create_sysfs_power_savings_entries(&cpu_sysdev_class);
+#endif
+
+       return err;
 }
index aa4185ee81fb2b1574fedeab47e21e9d4b7c3e39..6adbd9b1ae881121e9f377a121ec0c4e9355361c 100644 (file)
@@ -112,4 +112,9 @@ extern unsigned long node_remap_size[];
 
 extern cpumask_t cpu_coregroup_map(int cpu);
 
+#ifdef CONFIG_SMP
+#define mc_capable()   (boot_cpu_data.x86_max_cores > 1)
+#define smt_capable()  (smp_num_siblings > 1)
+#endif
+
 #endif /* _ASM_I386_TOPOLOGY_H */
index 616b5ed2aa7277e12885e6e35805d4fcacf748d9..937c212575239f3ec9ee9526e2c989289669f967 100644 (file)
@@ -112,6 +112,7 @@ void build_cpu_to_node_map(void);
 #define topology_core_id(cpu)                  (cpu_data(cpu)->core_id)
 #define topology_core_siblings(cpu)            (cpu_core_map[cpu])
 #define topology_thread_siblings(cpu)          (cpu_sibling_map[cpu])
+#define smt_capable()                          (smp_num_siblings > 1)
 #endif
 
 #include <asm-generic/topology.h>
index 92f3e5507d224cfc1cbf80e10d7d6bc09647a804..bbc3844b086fcadd9f529c69f5b12b6556530667 100644 (file)
@@ -93,5 +93,10 @@ static inline void sysfs_remove_device_from_node(struct sys_device *dev,
 
 #endif /* CONFIG_NUMA */
 
+#ifdef CONFIG_SMP
+#include <asm/cputable.h>
+#define smt_capable()          (cpu_has_feature(CPU_FTR_SMT))
+#endif
+
 #endif /* __KERNEL__ */
 #endif /* _ASM_POWERPC_TOPOLOGY_H */
index 0e234e201bd6b587375e17cdb450daae6c47b22c..98a6c613589dcbe29205d0705ebf871b6f577b22 100644 (file)
@@ -1,6 +1,9 @@
 #ifndef _ASM_SPARC64_TOPOLOGY_H
 #define _ASM_SPARC64_TOPOLOGY_H
 
+#include <asm/spitfire.h>
+#define smt_capable()  (tlb_type == hypervisor)
+
 #include <asm-generic/topology.h>
 
 #endif /* _ASM_SPARC64_TOPOLOGY_H */
index c4e46e7fa7ba781f9c086bf2ace317d105d9ba56..6e7a2e976b04fc8bc8a98213522fabf5c623af02 100644 (file)
@@ -59,6 +59,8 @@ extern int __node_distance(int, int);
 #define topology_core_id(cpu)                  (cpu_data[cpu].cpu_core_id)
 #define topology_core_siblings(cpu)            (cpu_core_map[cpu])
 #define topology_thread_siblings(cpu)          (cpu_sibling_map[cpu])
+#define mc_capable()                   (boot_cpu_data.x86_max_cores > 1)
+#define smt_capable()                  (smp_num_siblings > 1)
 #endif
 
 #include <asm-generic/topology.h>
index ab8ffc54423a3ef55a620b6041b84476bac988ac..0bc81a151e508e461caeebedb1fee42269d21052 100644 (file)
@@ -570,6 +570,11 @@ enum idle_type
 #define SD_WAKE_AFFINE         32      /* Wake task to waking CPU */
 #define SD_WAKE_BALANCE                64      /* Perform balancing at task wakeup */
 #define SD_SHARE_CPUPOWER      128     /* Domain members share cpu power */
+#define SD_POWERSAVINGS_BALANCE        256     /* Balance for power savings */
+
+#define BALANCE_FOR_POWER      ((sched_mc_power_savings || sched_smt_power_savings) \
+                                ? SD_POWERSAVINGS_BALANCE : 0)
+
 
 struct sched_group {
        struct sched_group *next;       /* Must be a circular list */
@@ -1412,6 +1417,11 @@ static inline void arch_pick_mmap_layout(struct mm_struct *mm)
 extern long sched_setaffinity(pid_t pid, cpumask_t new_mask);
 extern long sched_getaffinity(pid_t pid, cpumask_t *mask);
 
+#include <linux/sysdev.h>
+extern int sched_mc_power_savings, sched_smt_power_savings;
+extern struct sysdev_attribute attr_sched_mc_power_savings, attr_sched_smt_power_savings;
+extern int sched_create_sysfs_power_savings_entries(struct sysdev_class *cls);
+
 extern void normalize_rt_tasks(void);
 
 #ifdef CONFIG_PM
index a305ae2e44b6dde305d3afe241768e32c47d8907..ec1eca85290ade96c5f42da4d74acac2a8ae2407 100644 (file)
        .flags                  = SD_LOAD_BALANCE       \
                                | SD_BALANCE_NEWIDLE    \
                                | SD_BALANCE_EXEC       \
-                               | SD_WAKE_AFFINE,       \
+                               | SD_WAKE_AFFINE        \
+                               | BALANCE_FOR_POWER,    \
        .last_balance           = jiffies,              \
        .balance_interval       = 1,                    \
        .nr_balance_failed      = 0,                    \
index 122b75584a138d9fd3bb063f30f85d226b8855b9..54fa282657cc098cf47b1dd6e3bfc2fc9315410b 100644 (file)
@@ -1162,6 +1162,11 @@ static int sched_balance_self(int cpu, int flag)
        struct sched_domain *tmp, *sd = NULL;
 
        for_each_domain(cpu, tmp) {
+               /*
+                * If power savings logic is enabled for a domain, stop there.
+                */
+               if (tmp->flags & SD_POWERSAVINGS_BALANCE)
+                       break;
                if (tmp->flags & flag)
                        sd = tmp;
        }
@@ -2082,6 +2087,12 @@ find_busiest_group(struct sched_domain *sd, int this_cpu,
        unsigned long busiest_load_per_task, busiest_nr_running;
        unsigned long this_load_per_task, this_nr_running;
        int load_idx;
+#if defined(CONFIG_SCHED_MC) || defined(CONFIG_SCHED_SMT)
+       int power_savings_balance = 1;
+       unsigned long leader_nr_running = 0, min_load_per_task = 0;
+       unsigned long min_nr_running = ULONG_MAX;
+       struct sched_group *group_min = NULL, *group_leader = NULL;
+#endif
 
        max_load = this_load = total_load = total_pwr = 0;
        busiest_load_per_task = busiest_nr_running = 0;
@@ -2094,7 +2105,7 @@ find_busiest_group(struct sched_domain *sd, int this_cpu,
                load_idx = sd->idle_idx;
 
        do {
-               unsigned long load;
+               unsigned long load, group_capacity;
                int local_group;
                int i;
                unsigned long sum_nr_running, sum_weighted_load;
@@ -2127,18 +2138,76 @@ find_busiest_group(struct sched_domain *sd, int this_cpu,
                /* Adjust by relative CPU power of the group */
                avg_load = (avg_load * SCHED_LOAD_SCALE) / group->cpu_power;
 
+               group_capacity = group->cpu_power / SCHED_LOAD_SCALE;
+
                if (local_group) {
                        this_load = avg_load;
                        this = group;
                        this_nr_running = sum_nr_running;
                        this_load_per_task = sum_weighted_load;
                } else if (avg_load > max_load &&
-                          sum_nr_running > group->cpu_power / SCHED_LOAD_SCALE) {
+                          sum_nr_running > group_capacity) {
                        max_load = avg_load;
                        busiest = group;
                        busiest_nr_running = sum_nr_running;
                        busiest_load_per_task = sum_weighted_load;
                }
+
+#if defined(CONFIG_SCHED_MC) || defined(CONFIG_SCHED_SMT)
+               /*
+                * Busy processors will not participate in power savings
+                * balance.
+                */
+               if (idle == NOT_IDLE || !(sd->flags & SD_POWERSAVINGS_BALANCE))
+                       goto group_next;
+
+               /*
+                * If the local group is idle or completely loaded
+                * no need to do power savings balance at this domain
+                */
+               if (local_group && (this_nr_running >= group_capacity ||
+                                   !this_nr_running))
+                       power_savings_balance = 0;
+
+               /*
+                * If a group is already running at full capacity or idle,
+                * don't include that group in power savings calculations
+                */
+               if (!power_savings_balance || sum_nr_running >= group_capacity
+                   || !sum_nr_running)
+                       goto group_next;
+
+               /*
+                * Calculate the group which has the least non-idle load.
+                * This is the group from where we need to pick up the load
+                * for saving power
+                */
+               if ((sum_nr_running < min_nr_running) ||
+                   (sum_nr_running == min_nr_running &&
+                    first_cpu(group->cpumask) <
+                    first_cpu(group_min->cpumask))) {
+                       group_min = group;
+                       min_nr_running = sum_nr_running;
+                       min_load_per_task = sum_weighted_load /
+                                               sum_nr_running;
+               }
+
+               /*
+                * Calculate the group which is almost near its
+                * capacity but still has some space to pick up some load
+                * from other group and save more power
+                */
+               if (sum_nr_running <= group_capacity - 1)
+                       if (sum_nr_running > leader_nr_running ||
+                           (sum_nr_running == leader_nr_running &&
+                            first_cpu(group->cpumask) >
+                             first_cpu(group_leader->cpumask))) {
+                               group_leader = group;
+                               leader_nr_running = sum_nr_running;
+                       }
+
+group_next:
+#endif
                group = group->next;
        } while (group != sd->groups);
 
@@ -2247,7 +2316,16 @@ small_imbalance:
        return busiest;
 
 out_balanced:
+#if defined(CONFIG_SCHED_MC) || defined(CONFIG_SCHED_SMT)
+       if (idle == NOT_IDLE || !(sd->flags & SD_POWERSAVINGS_BALANCE))
+               goto ret;
 
+       if (this == group_leader && group_leader != group_min) {
+               *imbalance = min_load_per_task;
+               return group_min;
+       }
+ret:
+#endif
        *imbalance = 0;
        return NULL;
 }
@@ -2300,7 +2378,8 @@ static int load_balance(int this_cpu, runqueue_t *this_rq,
        int active_balance = 0;
        int sd_idle = 0;
 
-       if (idle != NOT_IDLE && sd->flags & SD_SHARE_CPUPOWER)
+       if (idle != NOT_IDLE && sd->flags & SD_SHARE_CPUPOWER &&
+           !sched_smt_power_savings)
                sd_idle = 1;
 
        schedstat_inc(sd, lb_cnt[idle]);
@@ -2389,7 +2468,8 @@ static int load_balance(int this_cpu, runqueue_t *this_rq,
                        sd->balance_interval *= 2;
        }
 
-       if (!nr_moved && !sd_idle && sd->flags & SD_SHARE_CPUPOWER)
+       if (!nr_moved && !sd_idle && sd->flags & SD_SHARE_CPUPOWER &&
+           !sched_smt_power_savings)
                return -1;
        return nr_moved;
 
@@ -2404,7 +2484,7 @@ out_one_pinned:
                        (sd->balance_interval < sd->max_interval))
                sd->balance_interval *= 2;
 
-       if (!sd_idle && sd->flags & SD_SHARE_CPUPOWER)
+       if (!sd_idle && sd->flags & SD_SHARE_CPUPOWER && !sched_smt_power_savings)
                return -1;
        return 0;
 }
@@ -2425,7 +2505,7 @@ static int load_balance_newidle(int this_cpu, runqueue_t *this_rq,
        int nr_moved = 0;
        int sd_idle = 0;
 
-       if (sd->flags & SD_SHARE_CPUPOWER)
+       if (sd->flags & SD_SHARE_CPUPOWER && !sched_smt_power_savings)
                sd_idle = 1;
 
        schedstat_inc(sd, lb_cnt[NEWLY_IDLE]);
@@ -2466,7 +2546,7 @@ static int load_balance_newidle(int this_cpu, runqueue_t *this_rq,
 
 out_balanced:
        schedstat_inc(sd, lb_balanced[NEWLY_IDLE]);
-       if (!sd_idle && sd->flags & SD_SHARE_CPUPOWER)
+       if (!sd_idle && sd->flags & SD_SHARE_CPUPOWER && !sched_smt_power_savings)
                return -1;
        sd->nr_balance_failed = 0;
        return 0;
@@ -5732,6 +5812,7 @@ static cpumask_t sched_domain_node_span(int node)
 }
 #endif
 
+int sched_smt_power_savings = 0, sched_mc_power_savings = 0;
 /*
  * At the moment, CONFIG_SCHED_SMT is never defined, but leave it in so we
  * can switch it on easily if needed.
@@ -6113,37 +6194,72 @@ static int build_sched_domains(const cpumask_t *cpu_map)
 #endif
 
        /* Calculate CPU power for physical packages and nodes */
+#ifdef CONFIG_SCHED_SMT
        for_each_cpu_mask(i, *cpu_map) {
-               int power;
                struct sched_domain *sd;
-#ifdef CONFIG_SCHED_SMT
                sd = &per_cpu(cpu_domains, i);
-               power = SCHED_LOAD_SCALE;
-               sd->groups->cpu_power = power;
+               sd->groups->cpu_power = SCHED_LOAD_SCALE;
+       }
 #endif
 #ifdef CONFIG_SCHED_MC
+       for_each_cpu_mask(i, *cpu_map) {
+               int power;
+               struct sched_domain *sd;
                sd = &per_cpu(core_domains, i);
-               power = SCHED_LOAD_SCALE + (cpus_weight(sd->groups->cpumask)-1)
+               if (sched_smt_power_savings)
+                       power = SCHED_LOAD_SCALE * cpus_weight(sd->groups->cpumask);
+               else
+                       power = SCHED_LOAD_SCALE + (cpus_weight(sd->groups->cpumask)-1)
                                            * SCHED_LOAD_SCALE / 10;
                sd->groups->cpu_power = power;
+       }
+#endif
 
+       for_each_cpu_mask(i, *cpu_map) {
+               struct sched_domain *sd;
+#ifdef CONFIG_SCHED_MC
                sd = &per_cpu(phys_domains, i);
+               if (i != first_cpu(sd->groups->cpumask))
+                       continue;
 
-               /*
-                * This has to be < 2 * SCHED_LOAD_SCALE
-                * Lets keep it SCHED_LOAD_SCALE, so that
-                * while calculating NUMA group's cpu_power
-                * we can simply do
-                *  numa_group->cpu_power += phys_group->cpu_power;
-                *
-                * See "only add power once for each physical pkg"
-                * comment below
-                */
-               sd->groups->cpu_power = SCHED_LOAD_SCALE;
+               sd->groups->cpu_power = 0;
+               if (sched_mc_power_savings || sched_smt_power_savings) {
+                       int j;
+
+                       for_each_cpu_mask(j, sd->groups->cpumask) {
+                               struct sched_domain *sd1;
+                               sd1 = &per_cpu(core_domains, j);
+                               /*
+                                * for each core we will add once
+                                * to the group in physical domain
+                                */
+                               if (j != first_cpu(sd1->groups->cpumask))
+                                       continue;
+
+                               if (sched_smt_power_savings)
+                                       sd->groups->cpu_power += sd1->groups->cpu_power;
+                               else
+                                       sd->groups->cpu_power += SCHED_LOAD_SCALE;
+                       }
+               } else
+                       /*
+                        * This has to be < 2 * SCHED_LOAD_SCALE
+                        * Lets keep it SCHED_LOAD_SCALE, so that
+                        * while calculating NUMA group's cpu_power
+                        * we can simply do
+                        *  numa_group->cpu_power += phys_group->cpu_power;
+                        *
+                        * See "only add power once for each physical pkg"
+                        * comment below
+                        */
+                       sd->groups->cpu_power = SCHED_LOAD_SCALE;
 #else
+               int power;
                sd = &per_cpu(phys_domains, i);
-               power = SCHED_LOAD_SCALE + SCHED_LOAD_SCALE *
-                               (cpus_weight(sd->groups->cpumask)-1) / 10;
+               if (sched_smt_power_savings)
+                       power = SCHED_LOAD_SCALE * cpus_weight(sd->groups->cpumask);
+               else
+                       power = SCHED_LOAD_SCALE;
                sd->groups->cpu_power = power;
 #endif
        }
@@ -6244,6 +6360,80 @@ int partition_sched_domains(cpumask_t *partition1, cpumask_t *partition2)
        return err;
 }
 
+#if defined(CONFIG_SCHED_MC) || defined(CONFIG_SCHED_SMT)
+int arch_reinit_sched_domains(void)
+{
+       int err;
+
+       lock_cpu_hotplug();
+       detach_destroy_domains(&cpu_online_map);
+       err = arch_init_sched_domains(&cpu_online_map);
+       unlock_cpu_hotplug();
+
+       return err;
+}
+
+static ssize_t sched_power_savings_store(const char *buf, size_t count, int smt)
+{
+       int ret;
+
+       if (buf[0] != '0' && buf[0] != '1')
+               return -EINVAL;
+
+       if (smt)
+               sched_smt_power_savings = (buf[0] == '1');
+       else
+               sched_mc_power_savings = (buf[0] == '1');
+
+       ret = arch_reinit_sched_domains();
+
+       return ret ? ret : count;
+}
+
+int sched_create_sysfs_power_savings_entries(struct sysdev_class *cls)
+{
+       int err = 0;
+#ifdef CONFIG_SCHED_SMT
+       if (smt_capable())
+               err = sysfs_create_file(&cls->kset.kobj,
+                                       &attr_sched_smt_power_savings.attr);
+#endif
+#ifdef CONFIG_SCHED_MC
+       if (!err && mc_capable())
+               err = sysfs_create_file(&cls->kset.kobj,
+                                       &attr_sched_mc_power_savings.attr);
+#endif
+       return err;
+}
+#endif
+
+#ifdef CONFIG_SCHED_MC
+static ssize_t sched_mc_power_savings_show(struct sys_device *dev, char *page)
+{
+       return sprintf(page, "%u\n", sched_mc_power_savings);
+}
+static ssize_t sched_mc_power_savings_store(struct sys_device *dev, const char *buf, size_t count)
+{
+       return sched_power_savings_store(buf, count, 0);
+}
+SYSDEV_ATTR(sched_mc_power_savings, 0644, sched_mc_power_savings_show,
+           sched_mc_power_savings_store);
+#endif
+
+#ifdef CONFIG_SCHED_SMT
+static ssize_t sched_smt_power_savings_show(struct sys_device *dev, char *page)
+{
+       return sprintf(page, "%u\n", sched_smt_power_savings);
+}
+static ssize_t sched_smt_power_savings_store(struct sys_device *dev, const char *buf, size_t count)
+{
+       return sched_power_savings_store(buf, count, 1);
+}
+SYSDEV_ATTR(sched_smt_power_savings, 0644, sched_smt_power_savings_show,
+           sched_smt_power_savings_store);
+#endif
+
+
 #ifdef CONFIG_HOTPLUG_CPU
 /*