--- /dev/null
+#!/bin/sh
+#
+# Copyright (C) 1999-2002 Riccardo Facchetti <riccardo@master.oasi.gpa.it>
+#
+# for apcupsd release 3.14.1 (04 May 2007) - unknown
+#
+# platforms/apccontrol. Generated from apccontrol.in by configure.
+#
+# Note, this is a generic file that can be used by most
+# systems. If a particular system needs to have something
+# special, start with this file, and put a copy in the
+# platform subdirectory.
+#
+
+#
+# These variables are needed for set up the autoconf other variables.
+#
+prefix=/usr
+exec_prefix=/usr
+
+APCPID=/var/run/apcupsd.pid
+APCUPSD=/usr/sbin/apcupsd
+SHUTDOWN=/sbin/shutdown
+SCRIPTSHELL=/bin/sh
+SCRIPTDIR=/etc/apcupsd
+WALL=true
+
+#
+# Concatenate all output from this script to the events file
+# Note, the following kills the script in a power fail situation
+# where the disks are mounted read-only.
+# exec >>/var/log/apcupsd.events 2>&1
+
+#
+# This piece is to substitute the default behaviour with your own script,
+# perl, or C program.
+# You can customize every single command creating an executable file (may be a
+# script or a compiled program) and calling it the same as the $1 parameter
+# passed by apcupsd to this script.
+#
+# After executing your script, apccontrol continues with the default action.
+# If you do not want apccontrol to continue, exit your script with exit
+# code 99. E.g. "exit 99".
+#
+# WARNING: the apccontrol file will be overwritten every time you update your
+# apcupsd, doing `make install'. Your own customized scripts will _not_ be
+# overwritten. If you wish to make changes to this file (discouraged), you
+# should change apccontrol.sh.in and then rerun the configure process.
+#
+if [ -f ${SCRIPTDIR}/${1} -a -x ${SCRIPTDIR}/${1} ]
+then
+ ${SCRIPTDIR}/${1} ${2} ${3} ${4}
+ # exit code 99 means he does not want us to do default action
+ if [ $? = 99 ] ; then
+ exit 0
+ fi
+fi
+
+case "$1" in
+ killpower)
+ echo "Apccontrol doing: ${APCUPSD} --killpower on UPS ${2}"
+ sleep 10
+ ${APCUPSD} --killpower
+ echo "Apccontrol has done: ${APCUPSD} --killpower on UPS ${2}" | ${WALL}
+ ;;
+ commfailure)
+ echo "Warning communications lost with UPS ${2}" | ${WALL}
+ ;;
+ commok)
+ echo "Communications restored with UPS ${2}" | ${WALL}
+ ;;
+#
+# powerout, onbattery, offbattery, mainsback events occur
+# in that order.
+#
+ powerout)
+ echo "Warning power loss detected on UPS ${2}" | ${WALL}
+ ;;
+ onbattery)
+ echo "Power failure on UPS ${2}. Running on batteries." | ${WALL}
+ ;;
+ offbattery)
+ ;;
+ mainsback)
+ echo "Power has returned on UPS ${2}..." | ${WALL}
+ if [ -f /etc/powerfail ] ; then
+ printf "Continuing with shutdown." | ${WALL}
+ fi
+ ;;
+ failing)
+ echo "Battery power exhaused on UPS ${2}. Doing shutdown." | ${WALL}
+ ;;
+ timeout)
+ echo "Battery time limit exceeded on UPS ${2}. Doing shutdown." | ${WALL}
+ ;;
+ loadlimit)
+ echo "Remaining battery charge below limit on UPS ${2}. Doing shutdown." | ${WALL}
+ ;;
+ runlimit)
+ echo "Remaining battery runtime below limit on UPS ${2}. Doing shutdown." | ${WALL}
+ ;;
+ doreboot)
+ echo "UPS ${2} initiating Reboot Sequence" | ${WALL}
+ ${SHUTDOWN} -r now "apcupsd UPS ${2} initiated reboot"
+ ;;
+ doshutdown)
+ echo "UPS ${2} initiated Shutdown Sequence" | ${WALL}
+ ${SHUTDOWN} -h now "apcupsd UPS ${2} initiated shutdown"
+ ;;
+ annoyme)
+ echo "Power problems with UPS ${2}. Please logoff." | ${WALL}
+ ;;
+ emergency)
+ echo "Emergency Shutdown. Possible battery failure on UPS ${2}." | ${WALL}
+ ;;
+ changeme)
+ echo "Emergency! Batteries have failed on UPS ${2}. Change them NOW" | ${WALL}
+ ;;
+ remotedown)
+ echo "Remote Shutdown. Beginning Shutdown Sequence." | ${WALL}
+ ;;
+ restartme)
+ echo -n "Restarting APCUPSD Power Management: "
+ THEPID=`cat ${APCPID}`
+ kill ${THEPID}
+ rm -f ${APCPID}
+ rm -f /etc/powerfail
+ rm -f /etc/nologin
+ sleep 5
+ `${APCUPSD}`
+ echo "apcupsd"
+ ;;
+ startselftest)
+ ;;
+ endselftest)
+ ;;
+ battdetach)
+ ;;
+ battattach)
+ ;;
+ *) echo "Usage: ${0##*/} command"
+ echo " warning: this script is intended to be launched by"
+ echo " apcupsd and should never be launched by users."
+ exit 1
+ ;;
+esac
--- /dev/null
+## apcupsd.conf v1.1 ##
+#
+# for apcupsd release 3.14.1 (04 May 2007) - unknown
+#
+# "apcupsd" POSIX config file
+
+#
+# ========= General configuration parameters ============
+#
+
+# UPSNAME xxx
+# Use this to give your UPS a name in log files and such. This
+# is particulary useful if you have multiple UPSes. This does not
+# set the EEPROM. It should be 8 characters or less.
+UPSNAME ups1
+
+# UPSCABLE <cable>
+# Defines the type of cable connecting the UPS to your computer.
+#
+# Possible generic choices for <cable> are:
+# simple, smart, ether, usb
+#
+# Or a specific cable model number may be used:
+# 940-0119A, 940-0127A, 940-0128A, 940-0020B,
+# 940-0020C, 940-0023A, 940-0024B, 940-0024C,
+# 940-1524C, 940-0024G, 940-0095A, 940-0095B,
+# 940-0095C, M-04-02-2000
+#
+UPSCABLE smart
+
+# To get apcupsd to work, in addition to defining the cable
+# above, you must also define a UPSTYPE, which corresponds to
+# the type of UPS you have (see the Description for more details).
+# You must also specify a DEVICE, sometimes referred to as a port.
+# For USB UPSes, please leave the DEVICE directive blank. For
+# other UPS types, you must specify an appropriate port or address.
+#
+# UPSTYPE DEVICE Description
+# apcsmart /dev/tty** Newer serial character device,
+# appropriate for SmartUPS models using
+# a serial cable (not USB).
+#
+# usb <BLANK> Most new UPSes are USB. A blank DEVICE
+# setting enables autodetection, which is
+# the best choice for most installations.
+#
+# net hostname:port Network link to a master apcupsd
+# through apcupsd's Network Information
+# Server. This is used if you don't have
+# a UPS directly connected to your computer.
+#
+# snmp hostname:port:vendor:community
+# SNMP Network link to an SNMP-enabled
+# UPS device. Vendor is the MIB used by
+# the UPS device: can be "APC", "APC_NOTRAP"
+# or "RFC" where APC is the powernet MIB,
+# "APC_NOTRAP" is powernet with SNMP trap
+# catching disabled, and RFC is the IETF's
+# rfc1628 UPS-MIB. You usually want "APC".
+# Port is usually 161. Community is usually
+# "private".
+#
+# dumb /dev/tty** Old serial character device for use
+# with simple-signaling UPSes.
+#
+# pcnet ipaddr:username:passphrase
+# PowerChute Network Shutdown protocol
+# which can be used as an alternative to SNMP
+# with AP9617 family of smart slot cards.
+# ipaddr is the IP address of the UPS mgmt
+# card. username and passphrase are the
+# credentials for which the card has been
+# configured.
+#
+UPSTYPE apcsmart
+DEVICE /dev/ttyS0
+
+
+# LOCKFILE <path to lockfile>
+# Path for device lock file. Not used on Win32.
+LOCKFILE /var/lock
+
+# SCRIPTDIR <path to script directory>
+# Directory in which apccontrol and event scripts are located.
+SCRIPTDIR /etc/apcupsd
+
+# PWRFAILDIR <path to powerfail directory>
+# Directory in which to write the powerfail flag file. This file
+# is created when apcupsd initiates a system shutdown and is
+# checked in the OS halt scripts to determine if a killpower
+# (turning off UPS output power) is required.
+PWRFAILDIR /etc
+
+# NOLOGINDIR <path to nologin directory>
+# Directory in which to write the nologin file. The existence
+# of this flag file tells the OS to disallow new logins.
+NOLOGINDIR /etc
+
+
+#
+# ======== Configuration parameters used during power failures ==========
+#
+
+# The ONBATTERYDELAY is the time in seconds from when a power failure
+# is detected until we react to it with an onbattery event.
+#
+# This means that, apccontrol will be called with the powerout argument
+# immediately when a power failure is detected. However, the
+# onbattery argument is passed to apccontrol only after the
+# ONBATTERYDELAY time. If you don't want to be annoyed by short
+# powerfailures, make sure that apccontrol powerout does nothing
+# i.e. comment out the wall.
+#ONBATTERYDELAY 6
+
+#
+# Note: BATTERYLEVEL, MINUTES, and TIMEOUT work in conjunction, so
+# the first that occurs will cause the initation of a shutdown.
+#
+
+# If during a power failure, the remaining battery percentage
+# (as reported by the UPS) is below or equal to BATTERYLEVEL,
+# apcupsd will initiate a system shutdown.
+BATTERYLEVEL 5
+
+# If during a power failure, the remaining runtime in minutes
+# (as calculated internally by the UPS) is below or equal to MINUTES,
+# apcupsd, will initiate a system shutdown.
+MINUTES 3
+
+# If during a power failure, the UPS has run on batteries for TIMEOUT
+# many seconds or longer, apcupsd will initiate a system shutdown.
+# A value of 0 disables this timer.
+#
+# Note, if you have a Smart UPS, you will most likely want to disable
+# this timer by setting it to zero. That way, you UPS will continue
+# on batteries until either the % charge remaing drops to or below BATTERYLEVEL,
+# or the remaining battery runtime drops to or below MINUTES. Of course,
+# if you are testing, setting this to 60 causes a quick system shutdown
+# if you pull the power plug.
+# If you have an older dumb UPS, you will want to set this to less than
+# the time you know you can run on batteries.
+TIMEOUT 0
+
+# Time in seconds between annoying users to signoff prior to
+# system shutdown. 0 disables.
+ANNOY 300
+
+# Initial delay after power failure before warning users to get
+# off the system.
+ANNOYDELAY 60
+
+# The condition which determines when users are prevented from
+# logging in during a power failure.
+# NOLOGON <string> [ disable | timeout | percent | minutes | always ]
+NOLOGON disable
+
+# If KILLDELAY is non-zero, apcupsd will continue running after a
+# shutdown has been requested, and after the specified time in
+# seconds attempt to kill the power. This is for use on systems
+# where apcupsd cannot regain control after a shutdown.
+# KILLDELAY <seconds> 0 disables
+KILLDELAY 0
+
+#
+# ==== Configuration statements for Network Information Server ====
+#
+
+# NETSERVER [ on | off ] on enables, off disables the network
+# information server. If netstatus is on, a network information
+# server process will be started for serving the STATUS and
+# EVENT data over the network (used by CGI programs).
+NETSERVER on
+
+# NISIP <dotted notation ip address>
+# IP address on which NIS server will listen for incoming connections.
+# This is useful if your server is multi-homed (has more than one
+# network interface and IP address). Default value is 0.0.0.0 which
+# means any incoming request will be serviced. Alternatively, you can
+# configure this setting to any specific IP address of your server and
+# NIS will listen for connections only on that interface. Use the
+# loopback address (127.0.0.1) to accept connections only from the
+# local machine.
+NISIP 0.0.0.0
+
+# NISPORT <port> default is 3551 as registered with the IANA
+# port to use for sending STATUS and EVENTS data over the network.
+# It is not used unless NETSERVER is on. If you change this port,
+# you will need to change the corresponding value in the cgi directory
+# and rebuild the cgi programs.
+NISPORT 3551
+
+# If you want the last few EVENTS to be available over the network
+# by the network information server, you must define an EVENTSFILE.
+EVENTSFILE /var/log/apcupsd.events
+
+# EVENTSFILEMAX <kilobytes>
+# By default, the size of the EVENTSFILE will be not be allowed to exceed
+# 10 kilobytes. When the file grows beyond this limit, older EVENTS will
+# be removed from the beginning of the file (first in first out). The
+# parameter EVENTSFILEMAX can be set to a different kilobyte value, or set
+# to zero to allow the EVENTSFILE to grow without limit.
+EVENTSFILEMAX 10
+
+#
+# ========== Configuration statements used if sharing =============
+# a UPS with more than one machine
+
+# NETTIME <int>
+# Interval (in seconds) at which the NIS client polls the server.
+# Used only when this apcupsd is a network client (UPSTYPE net).
+#NETTIME 60
+
+#
+# Remaining items are for ShareUPS (APC expansion card) ONLY
+#
+
+# UPSCLASS [ standalone | shareslave | sharemaster ]
+# Normally standalone unless you share an UPS using an APC ShareUPS
+# card.
+UPSCLASS standalone
+
+# UPSMODE [ disable | share ]
+# Normally disable unless you share an UPS using an APC ShareUPS card.
+UPSMODE disable
+
+#
+# ===== Configuration statements to control apcupsd system logging ========
+#
+
+# Time interval in seconds between writing the STATUS file; 0 disables
+STATTIME 0
+
+# Location of STATUS file (written to only if STATTIME is non-zero)
+STATFILE /var/log/apcupsd.status
+
+# LOGSTATS [ on | off ] on enables, off disables
+# Note! This generates a lot of output, so if
+# you turn this on, be sure that the
+# file defined in syslog.conf for LOG_NOTICE is a named pipe.
+# You probably do not want this on.
+LOGSTATS off
+
+# Time interval in seconds between writing the DATA records to
+# the log file. 0 disables.
+DATATIME 0
+
+# FACILITY defines the logging facility (class) for logging to syslog.
+# If not specified, it defaults to "daemon". This is useful
+# if you want to separate the data logged by apcupsd from other
+# programs.
+#FACILITY DAEMON
+
+#
+# ========== Configuration statements used in updating the UPS EPROM =========
+#
+
+#
+# These statements are used only by apctest when choosing "Set EEPROM with conf
+# file values" from the EEPROM menu. THESE STATEMENTS HAVE NO EFFECT ON APCUPSD.
+#
+
+# UPS name, max 8 characters
+#UPSNAME UPS_IDEN
+
+# Battery date - 8 characters
+#BATTDATE mm/dd/yy
+
+# Sensitivity to line voltage quality (H cause faster transfer to batteries)
+# SENSITIVITY H M L (default = H)
+#SENSITIVITY H
+
+# UPS delay after power return (seconds)
+# WAKEUP 000 060 180 300 (default = 0)
+#WAKEUP 60
+
+# UPS Grace period after request to power off (seconds)
+# SLEEP 020 180 300 600 (default = 20)
+#SLEEP 180
+
+# Low line voltage causing transfer to batteries
+# The permitted values depend on your model as defined by last letter
+# of FIRMWARE or APCMODEL. Some representative values are:
+# D 106 103 100 097
+# M 177 172 168 182
+# A 092 090 088 086
+# I 208 204 200 196 (default = 0 => not valid)
+#LOTRANSFER 208
+
+# High line voltage causing transfer to batteries
+# The permitted values depend on your model as defined by last letter
+# of FIRMWARE or APCMODEL. Some representative values are:
+# D 127 130 133 136
+# M 229 234 239 224
+# A 108 110 112 114
+# I 253 257 261 265 (default = 0 => not valid)
+#HITRANSFER 253
+
+# Battery charge needed to restore power
+# RETURNCHARGE 00 15 50 90 (default = 15)
+#RETURNCHARGE 15
+
+# Alarm delay
+# 0 = zero delay after pwr fail, T = power fail + 30 sec, L = low battery, N = never
+# BEEPSTATE 0 T L N (default = 0)
+#BEEPSTATE T
+
+# Low battery warning delay in minutes
+# LOWBATT 02 05 07 10 (default = 02)
+#LOWBATT 2
+
+# UPS Output voltage when running on batteries
+# The permitted values depend on your model as defined by last letter
+# of FIRMWARE or APCMODEL. Some representative values are:
+# D 115
+# M 208
+# A 100
+# I 230 240 220 225 (default = 0 => not valid)
+#OUTPUTVOLTS 230
+
+# Self test interval in hours 336=2 weeks, 168=1 week, ON=at power on
+# SELFTEST 336 168 ON OFF (default = 336)
+#SELFTEST 336