RT305x/RT5350 SoCs require the switch to be reset before touching the ethernet
interface, otherwise the driver will panic.
As we already init the ethernet in preinit we therefor need to reset the switch
before that.
Signed-off-by: Felix Kaechele <felix@fetzig.org>
SVN-Revision: 37027
fi
local wanports=""
local lanports=""
- swconfig dev rt305x set reset 1
for port in 5 4 3 2 1 0; do
if [ `swconfig dev rt305x port $port get disable` = "1" ]; then
continue
. /lib/ramips.sh
ramips_set_preinit_iface() {
- local board=$(ramips_board_name)
-
- case "$board" in
- mpr-a2)
- #TODO
- # Ralink ethernet driver cannot re-open ethernet if it is opened during preinit and then closed.
- # Looks like Ralink ethernet driver has a problem.
- # Temporary solution is not to open ethernet during preinit.
- return 0
- ;;
- esac
+ RT3X5X=`cat /proc/cpuinfo | egrep "(RT3.5|RT5350)"`
+ if [ -n "${RT3X5X}" ]; then
+ swconfig dev rt305x set reset 1
+ fi
ifname=eth0
}