PHY counter overflows need to be checked for the old ANI version,
because of its use of interrupt based counter overflow reports when
the counters exceed the configured thresholds.
Signed-off-by: Felix Fietkau <nbd@openwrt.org>
Signed-off-by: John W. Linville <linville@tuxdriver.com>
phyCnt1 = REG_READ(ah, AR_PHY_ERR_1);
phyCnt2 = REG_READ(ah, AR_PHY_ERR_2);
- if (use_new_ani(ah) && (phyCnt1 < ofdm_base || phyCnt2 < cck_base)) {
+ if (!use_new_ani(ah) && (phyCnt1 < ofdm_base || phyCnt2 < cck_base)) {
if (phyCnt1 < ofdm_base) {
ath_print(common, ATH_DBG_ANI,
"phyCnt1 0x%x, resetting "