ath79: fix OCEDO Raccoon 10Mbit PLL value
authorDavid Bauer <mail@david-bauer.net>
Mon, 22 Apr 2019 19:29:42 +0000 (21:29 +0200)
committerPetr Štetiar <ynezz@true.cz>
Sun, 5 May 2019 19:11:01 +0000 (21:11 +0200)
This corrects the PLL value for 10 Mbit/s links on the OCEDO Raccoon.
Prior to this patch, 10 Mbit/s links would not transmit data.

It is worth mentioning that the vendor firmware used the same PLL
settings and 10Mbit/s was also not working there.

All other link-modes are working correctly without any packet loss.

Signed-off-by: David Bauer <mail@david-bauer.net>
target/linux/ath79/dts/ar9344_ocedo_raccoon.dts

index 0875c319b9e6654e949f13e7aec657596f9c43ea..a1a912383f620f538b6e05217e9ae18e4a2677b6 100644 (file)
 &eth0 {
        status = "okay";
 
-       /* default for ar934x, except for 1000M */
-       pll-data = <0x06000000 0x00000101 0x00001616>;
+       pll-data = <0x06000000 0x00000101 0x00001313>;
 
        mtd-mac-address = <&art 0x0>;