For fixed regulator, setting .n_voltages = 1 and .fixed_uV is enough,
no need to set .min_uV and .list_volage.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Signed-off-by: Mark Brown <broonie@kernel.org>
}
static const struct regulator_ops stm32_pwr_reg_ops = {
- .list_voltage = regulator_list_voltage_linear,
.enable = stm32_pwr_reg_enable,
.disable = stm32_pwr_reg_disable,
.is_enabled = stm32_pwr_reg_is_enabled,
.of_match = of_match_ptr(_name), \
.n_voltages = 1, \
.type = REGULATOR_VOLTAGE, \
- .min_uV = _volt, \
.fixed_uV = _volt, \
.ops = &stm32_pwr_reg_ops, \
.enable_mask = _en, \