The ST variants of the PL031 all require bit 26 in the control register
to be set before they work properly. Discovered this when testing on
the Nomadik board where it would suprisingly just stand still.
Signed-off-by: Linus Walleij <linus.walleij@linaro.org>
Cc: Mian Yousaf Kaukab <mian.yousaf.kaukab@stericsson.com>
Cc: Alessandro Rubini <rubini@unipv.it>
Cc: <stable@vger.kernel.org>
Signed-off-by: Andrew Morton <akpm@linux-foundation.org>
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
dev_dbg(&adev->dev, "revision = 0x%01x\n", ldata->hw_revision);
/* Enable the clockwatch on ST Variants */
- if ((ldata->hw_designer == AMBA_VENDOR_ST) &&
- (ldata->hw_revision > 1))
+ if (ldata->hw_designer == AMBA_VENDOR_ST)
writel(readl(ldata->base + RTC_CR) | RTC_CR_CWEN,
ldata->base + RTC_CR);