Input: wacom_w8001 - report resolution to userland
authorPing Cheng <pinglinux@gmail.com>
Tue, 1 Feb 2011 05:06:38 +0000 (21:06 -0800)
committerDmitry Torokhov <dmitry.torokhov@gmail.com>
Tue, 1 Feb 2011 05:32:24 +0000 (21:32 -0800)
Serial devices send both pen and touch data through the same logical
port. Since we scaled touch to pen maximum, we use pen resolution
for touch as well here.

This is under the assumption that pen and touch share the same physical
surface. In the case when a small physical dimensional difference occurs
between pen and touch, we assume the tolerance for touch point precision
is higher than pen and the difference is within touch point tolerance.

A per-MT tool based resolution mechanism should be introduced if the
above assumption does not hold true for the pen and touch devices any
more.

Signed-off-by: Ping Cheng <pingc@wacom.com>
Reviewed-by: Henrik Rydberg <rydberg@euromail.se>
Signed-off-by: Dmitry Torokhov <dtor@mail.ru>
drivers/input/touchscreen/wacom_w8001.c

index 5cb8449c909d99e503488eff60dc98e8601c222d..c14412ef4648ba45bd78d81a7367ca670fc444f2 100644 (file)
@@ -51,6 +51,10 @@ MODULE_LICENSE("GPL");
 #define W8001_PKTLEN_TPCCTL    11      /* control packet */
 #define W8001_PKTLEN_TOUCH2FG  13
 
+/* resolution in points/mm */
+#define W8001_PEN_RESOLUTION    100
+#define W8001_TOUCH_RESOLUTION  10
+
 struct w8001_coord {
        u8 rdy;
        u8 tsw;
@@ -198,7 +202,7 @@ static void parse_touchquery(u8 *data, struct w8001_touch_query *query)
                query->y = 1024;
                if (query->panel_res)
                        query->x = query->y = (1 << query->panel_res);
-               query->panel_res = 10;
+               query->panel_res = W8001_TOUCH_RESOLUTION;
        }
 }
 
@@ -394,6 +398,8 @@ static int w8001_setup(struct w8001 *w8001)
 
                input_set_abs_params(dev, ABS_X, 0, coord.x, 0, 0);
                input_set_abs_params(dev, ABS_Y, 0, coord.y, 0, 0);
+               input_abs_set_res(dev, ABS_X, W8001_PEN_RESOLUTION);
+               input_abs_set_res(dev, ABS_Y, W8001_PEN_RESOLUTION);
                input_set_abs_params(dev, ABS_PRESSURE, 0, coord.pen_pressure, 0, 0);
                if (coord.tilt_x && coord.tilt_y) {
                        input_set_abs_params(dev, ABS_TILT_X, 0, coord.tilt_x, 0, 0);
@@ -418,14 +424,17 @@ static int w8001_setup(struct w8001 *w8001)
                w8001->max_touch_x = touch.x;
                w8001->max_touch_y = touch.y;
 
-               /* scale to pen maximum */
                if (w8001->max_pen_x && w8001->max_pen_y) {
+                       /* if pen is supported scale to pen maximum */
                        touch.x = w8001->max_pen_x;
                        touch.y = w8001->max_pen_y;
+                       touch.panel_res = W8001_PEN_RESOLUTION;
                }
 
                input_set_abs_params(dev, ABS_X, 0, touch.x, 0, 0);
                input_set_abs_params(dev, ABS_Y, 0, touch.y, 0, 0);
+               input_abs_set_res(dev, ABS_X, touch.panel_res);
+               input_abs_set_res(dev, ABS_Y, touch.panel_res);
 
                switch (touch.sensor_id) {
                case 0: