realtek: tl-sg2008p: fix labeling of lan ports
authorAlexandru Gagniuc <mr.nuke.me@gmail.com>
Sun, 28 Aug 2022 23:08:50 +0000 (18:08 -0500)
committerSander Vanheule <sander@svanheule.net>
Mon, 29 Aug 2022 09:54:00 +0000 (11:54 +0200)
The SG2008P has its ethernet ports in the rear, and LEDs in the front.
The ports should be labeled lan8->lan1, not lan1->lan8. To resolve
this, fix the phy mapping in the "ports" node.

Signed-off-by: Alexandru Gagniuc <mr.nuke.me@gmail.com>
target/linux/realtek/dts-5.10/rtl8380_tplink_sg2008p-v1.dts

index 34b3d0456ba9c3882c566f5fb2cf3ba8c7d7e2b0..d464921e50f7fb1b77eab30f1473bfeba9e00212 100644 (file)
                #address-cells = <1>;
                #size-cells = <0>;
 
-               SWITCH_PORT(8, 1, internal)
-               SWITCH_PORT(9, 2, internal)
-               SWITCH_PORT(10, 3, internal)
-               SWITCH_PORT(11, 4, internal)
-               SWITCH_PORT(12, 5, internal)
-               SWITCH_PORT(13, 6, internal)
-               SWITCH_PORT(14, 7, internal)
-               SWITCH_PORT(15, 8, internal)
+               SWITCH_PORT(15, 1, internal)
+               SWITCH_PORT(14, 2, internal)
+               SWITCH_PORT(13, 3, internal)
+               SWITCH_PORT(12, 4, internal)
+               SWITCH_PORT(11, 5, internal)
+               SWITCH_PORT(10, 6, internal)
+               SWITCH_PORT(9, 7, internal)
+               SWITCH_PORT(8, 8, internal)
 
                port@28 {
                        ethernet = <&ethernet0>;