enum ar9003_cal_types {
IQ_MISMATCH_CAL = BIT(0),
+ TEMP_COMP_CAL = BIT(1),
};
static void ar9003_hw_setup_calibration(struct ath_hw *ah,
/* Kick-off cal */
REG_SET_BIT(ah, AR_PHY_TIMING4, AR_PHY_TIMING4_DO_CAL);
break;
+ case TEMP_COMP_CAL:
+ ath_dbg(common, CALIBRATE,
+ "starting Temperature Compensation Calibration\n");
+ REG_SET_BIT(ah, AR_CH0_THERM, AR_CH0_THERM_LOCAL);
+ REG_SET_BIT(ah, AR_CH0_THERM, AR_CH0_THERM_START);
+ break;
default:
ath_err(common, "Invalid calibration type\n");
break;
/*
* Accumulate cal measures for active chains
*/
- cur_caldata->calCollect(ah);
+ if (cur_caldata->calCollect)
+ cur_caldata->calCollect(ah);
ah->cal_samples++;
if (ah->cal_samples >= cur_caldata->calNumSamples) {
/*
* Process accumulated data
*/
- cur_caldata->calPostProc(ah, numChains);
+ if (cur_caldata->calPostProc)
+ cur_caldata->calPostProc(ah, numChains);
/* Calibration has finished. */
caldata->CalValid |= cur_caldata->calType;
ar9003_hw_iqcalibrate
};
+static const struct ath9k_percal_data temp_cal_single_sample = {
+ TEMP_COMP_CAL,
+ MIN_CAL_SAMPLES,
+ PER_MAX_LOG_COUNT,
+};
+
static void ar9003_hw_init_cal_settings(struct ath_hw *ah)
{
ah->iq_caldata.calData = &iq_cal_single_sample;
+ ah->temp_caldata.calData = &temp_cal_single_sample;
if (AR_SREV_9300_20_OR_LATER(ah)) {
ah->enabled_cals |= TX_IQ_CAL;
ah->enabled_cals |= TX_IQ_ON_AGC_CAL;
}
- ah->supp_cals = IQ_MISMATCH_CAL;
+ ah->supp_cals = IQ_MISMATCH_CAL | TEMP_COMP_CAL;
}
#define OFF_UPPER_LT 24
INIT_CAL(&ah->iq_caldata);
INSERT_CAL(ah, &ah->iq_caldata);
+ INIT_CAL(&ah->temp_caldata);
+ INSERT_CAL(ah, &ah->temp_caldata);
+
/* Initialize current pointer to first element in list */
ah->cal_list_curr = ah->cal_list;