Testing EP_FLAG_RUNNING in snd_complete_urb() before running the completion
logic allows us to save a few cpu cycles by returning early, skipping the
pending urb in case the stream was stopped; the stop logic handles the urb
and sets the completion callbacks to NULL.
Signed-off-by: Ioan-Adrian Ratiu <adi@adirat.com>
Signed-off-by: Takashi Iwai <tiwai@suse.de>
if (unlikely(atomic_read(&ep->chip->shutdown)))
goto exit_clear;
+ if (unlikely(!test_bit(EP_FLAG_RUNNING, &ep->flags)))
+ goto exit_clear;
+
if (usb_pipeout(ep->pipe)) {
retire_outbound_urb(ep, ctx);
/* can be stopped during retire callback */