The value written to MODE_REG in ip175c_reset() should be obviously MODE_VAL,
not RESET_VAL. Actually, this change is a NOP, because in the only case where
the MODE_REG is used, the two values are identical, but it makes the code
more readable.
Signed-off-by: Martin Mares <mj@ucw.cz>
Signed-off-by: Patrick Horn <patrick.horn@gmail.com>
SVN-Revision: 21713
}
if (REG_SUPP(state->regs->MODE_REG)) {
- err = setPhy(state, state->regs->MODE_REG, state->regs->RESET_VAL);
+ err = setPhy(state, state->regs->MODE_REG, state->regs->MODE_VAL);
if (err < 0)
return err;
err = getPhy(state, state->regs->MODE_REG);