From: Abhijeet Kolekar <abhijeet.kolekar@intel.com>
For 6X50 DC calibration needs to be initialized
else uCode will run an endless loop.
Enbale DC calibration in hw config.
Signed-off-by: Abhijeet Kolekar <abhijeet.kolekar@intel.com>
Signed-off-by: Reinette Chatre <reinette.chatre@intel.com>
Signed-off-by: John W. Linville <linville@tuxdriver.com>
/* Set initial sensitivity parameters */
/* Set initial calibration set */
priv->hw_params.sens = &iwl6000_sensitivity;
- priv->hw_params.calib_init_cfg =
+ switch (priv->hw_rev & CSR_HW_REV_TYPE_MSK) {
+ case CSR_HW_REV_TYPE_6x50:
+ priv->hw_params.calib_init_cfg =
BIT(IWL_CALIB_XTAL) |
+ BIT(IWL_CALIB_DC) |
BIT(IWL_CALIB_LO) |
BIT(IWL_CALIB_TX_IQ) |
BIT(IWL_CALIB_BASE_BAND);
+
+ break;
+ default:
+ priv->hw_params.calib_init_cfg =
+ BIT(IWL_CALIB_XTAL) |
+ BIT(IWL_CALIB_LO) |
+ BIT(IWL_CALIB_TX_IQ) |
+ BIT(IWL_CALIB_BASE_BAND);
+ break;
+ }
+
return 0;
}