Maxim MAX30102 heart rate and pulse oximeter sensor
+Maxim MAX30105 optical particle-sensing module
* https://datasheets.maximintegrated.com/en/ds/MAX30102.pdf
+* https://datasheets.maximintegrated.com/en/ds/MAX30105.pdf
Required properties:
- - compatible: must be "maxim,max30102"
+ - compatible: must be "maxim,max30102" or "maxim,max30105"
- reg: the I2C address of the sensor
- interrupt-parent: should be the phandle for the interrupt controller
- interrupts: the sole interrupt generated by the device
interrupt client node bindings.
Optional properties:
- - maxim,red-led-current-microamp: configuration for RED LED current
+ - maxim,red-led-current-microamp: configuration for red LED current
- maxim,ir-led-current-microamp: configuration for IR LED current
+ - maxim,green-led-current-microamp: configuration for green LED current
+ (max30105 only)
Note that each step is approximately 200 microamps, ranging from 0 uA to
50800 uA.