Juno: Use TZC-400 driver calls
authorJuan Castillo <juan.castillo@arm.com>
Thu, 4 Sep 2014 13:43:09 +0000 (14:43 +0100)
committerJuan Castillo <juan.castillo@arm.com>
Thu, 9 Oct 2014 16:15:24 +0000 (17:15 +0100)
commitef538c6f1b097d0a115e89aa89fb040d98e6594e
tree9a5d8406c5ffbccbab224b8c083d6da43989aa12
parent7e998c42ce1ffa16101cc712a3b914c311e29788
Juno: Use TZC-400 driver calls

This patch replaces direct accesses to the TZC-400 registers by the
appropiate calls to the generic driver available in the Trusted
Firmware in order to initialize the TrustZone Controller.

Functions related to the initialization of the secure memory,
like the TZC-400 configuration, have been moved to a new file
'plat_security.c'. This reorganization makes easier to set up
the secure memory from any BL stage.

TZC-400 initialization has been moved from BL1 to BL2 because BL1
does not access the non-secure memory. It is BL2's responsibility
to enable and configure the TZC-400 before loading the next BL
images.

In Juno, BL3-0 initializes some of the platform peripherals, like
the DDR controller. Thus, BL3-0 must be loaded before configuring
the TrustZone Controller. As a consequence, the IO layer
initialization has been moved to early platform initialization.

Fixes ARM-software/tf-issues#234

Change-Id: I83dde778f937ac8d2996f7377e871a2e77d9490e
bl2/bl2_main.c
plat/juno/bl1_plat_setup.c
plat/juno/bl2_plat_setup.c
plat/juno/juno_private.h
plat/juno/plat_security.c [new file with mode: 0644]
plat/juno/platform.mk