usb: dwc3: Add workaround for isoc start transfer failure
authorThinh Nguyen <thinh.nguyen@synopsys.com>
Thu, 15 Nov 2018 06:56:54 +0000 (22:56 -0800)
committerFelipe Balbi <felipe.balbi@linux.intel.com>
Mon, 26 Nov 2018 07:06:32 +0000 (09:06 +0200)
commitd92021f66063b30910255d70dc95e0d7b57f018f
tree25913e8c22e5a673e9e9e7c1b7ec30693e930c7c
parentdd74b96c74806da7a0e8cc794328950a2a7cb833
usb: dwc3: Add workaround for isoc start transfer failure

In DWC_usb31 version 1.70a-ea06 and prior, for highspeed and fullspeed
isochronous IN, BIT[15:14] of the 16-bit microframe number reported by
the XferNotReady event are invalid. The driver uses this number to
schedule the isochronous transfer and passes it to the START TRANSFER
command. Because this number is invalid, the command may fail. If
BIT[15:14] matches the internal 16-bit microframe, the START TRANSFER
command will pass and the transfer will start at the scheduled time, if
it is off by 1, the command will still pass, but the transfer will start
2 seconds in the future. For all other conditions, the START TRANSFER
command will fail with bus-expiry.

In order to workaround this issue, we can test for the correct
combination of BIT[15:14] by sending START TRANSFER commands with
different values of BIT[15:14]: 'b00, 'b01, 'b10, and 'b11. Each
combination is 2^14 uframe apart (or 2 seconds). 4 seconds into the
future will result in a bus-expiry status. As the result, within the 4
possible combinations for BIT[15:14], there will be 2 successful and 2
failure START COMMAND status. One of the 2 successful command status
will result in a 2-second delay start. The smaller BIT[15:14] value is
the correct combination.

Since there are only 4 outcomes and the results are ordered, we can
simply test 2 START TRANSFER commands with BIT[15:14] combinations 'b00
and 'b01 to deduce the smaller successful combination.

Let test0 = test status for combination 'b00 and test1 = test status for
'b01 of BIT[15:14]. The correct combination is as follow:

if test0 fails and test1 passes, BIT[15:14] is 'b01
if test0 fails and test1 fails, BIT[15:14] is 'b10
if test0 passes and test1 fails, BIT[15:14] is 'b11
if test0 passes and test1 passes, BIT[15:14] is 'b00

Synopsys STAR 9001202023: Wrong microframe number for isochronous IN
endpoints.

Signed-off-by: Thinh Nguyen <thinhn@synopsys.com>
Signed-off-by: Felipe Balbi <felipe.balbi@linux.intel.com>
drivers/usb/dwc3/core.c
drivers/usb/dwc3/core.h
drivers/usb/dwc3/gadget.c