lantiq: VGV7510KW22BRN - set the phy clock source
authorblogic <blogic@3c298f89-4303-0410-b956-a3cf2f4a3e73>
Mon, 2 May 2016 18:50:35 +0000 (18:50 +0000)
committerJo-Philipp Wich <jo@mein.io>
Tue, 10 May 2016 08:43:12 +0000 (10:43 +0200)
commitd4de9f72f31c4716f78fea8950261a3bdafdbccb
tree31ad3a67a709ecdd0f9780138a449c2f051c3a2e
parent44cace4dabe186a486d6713de6196bc7cea2228b
lantiq: VGV7510KW22BRN - set the phy clock source

VGV7510KW2 with VRX288 v1.2 has brnboot 1.8 installed. Starting with
this brnboot version, the "GPHY Clock Source" isn't set anymore by
brnboot, with the result that xrx200-net fails to probe/initialize the
phys.

Use the phy clock source device tree binding to specify the clock source.

Signed-off-by: Mathias Kresin <openwrt@kresin.me>
SVN-Revision: 49284
target/linux/lantiq/dts/VGV7510KW22BRN.dts