dt-bindings: usb: fusb302: Use usb-connector bindings for configuration
There are now generic usb-connector bindings which can be used
to define a port controllers configuration for USB-PD, so device
specific bindings are no longer necessary.
This update deprecates 'fcs,operating-sink-microwatt', and references
the 'usb-connector' bindings instead to achieve the required port
config.
Signed-off-by: Adam Thomson <Adam.Thomson.Opensource@diasemi.com>
Reviewed-by: Rob Herring <robh@kernel.org>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>