blkio-throttle: Fix possible multiplication overflow in iops calculations
o User can specify max iops value of 32bit (UINT_MAX), through cgroup
interface. If a user has specified say
4294967294 (UNIT_MAX - 2), then
on 32bit platform, following multiplication can overflow.
io_allowed = (tg->iops[rw] * jiffy_elapsed_rnd)
o Explicitly cast the multiplication to 64bit and then perform division and
then check whether result is still great then UNINT_MAX.
Signed-off-by: Vivek Goyal <vgoyal@redhat.com>
Signed-off-by: Jens Axboe <jaxboe@fusionio.com>