Merge tag 'for-linus-20150422' of git://git.infradead.org/linux-mtd
authorLinus Torvalds <torvalds@linux-foundation.org>
Wed, 22 Apr 2015 19:00:44 +0000 (12:00 -0700)
committerLinus Torvalds <torvalds@linux-foundation.org>
Wed, 22 Apr 2015 19:00:44 +0000 (12:00 -0700)
commita62d016cece2fce1d5e4eedf36b17f03a7a5c78e
treeac37b4835be5f4fe0e04611fdb40c85abb98ec78
parent7c034dfd58bbc056280262887acf5b7a98944d0a
parent3e550d2396d9deef77328237ed992e19dcfefca5
Merge tag 'for-linus-20150422' of git://git.infradead.org/linux-mtd

Pull MTD updates from Brian Norris:
 "Common MTD:

   - Add Kconfig option for keeping both the 'master' and 'partition'
     MTDs registered as devices.  This would really make a better
     default if we could do it over, as it allows a lot more flexibility
     in (1) determining the flash topology of the system from user-space
     and (2) adding temporary partitions at runtime (ioctl(BLKPG)).

     Unfortunately, this would possibly cause user-space breakage, as it
     will cause renumbering of the /dev/mtdX devices.  We'll see if we
     can change this in the future, as there have already been a few
     people looking for this feature, and I know others have just been
     working around our current limitations instead of fixing them this
     way.

   - Along with the previous change, add some additional information to
     sysfs, so user-space can read the offset of each partition within
     its master device

  SPI NOR:

   - add new device tree compatible binding to represent the
     mostly-compatible class of SPI NOR flash which can be detected by
     their extended JEDEC ID bytes, cutting down the duplication of our
     ID tables

   - misc.  new IDs

  Various other miscellaneous fixes and changes"

* tag 'for-linus-20150422' of git://git.infradead.org/linux-mtd: (53 commits)
  mtd: spi-nor: Add support for Macronix mx25u6435f serial flash
  mtd: spi-nor: Add support for Winbond w25q64dw serial flash
  mtd: spi-nor: add support for the Winbond W25X05 flash
  mtd: spi-nor: support en25s64 device
  mtd: m25p80: bind to "nor-jedec" ID, for auto-detection
  Documentation: devicetree: m25p80: add "nor-jedec" binding
  mtd: Make MTD tests cancelable
  mtd: mtd_oobtest: Fix bitflip_limit usage in test case 3
  mtd: docg3: remove invalid __exit annotations
  mtd: fsl_ifc_nand: use msecs_to_jiffies for time conversion
  mtd: atmel_nand: don't map the ROM table if no pmecc table offset in DT
  mtd: atmel_nand: add a definition for the oob reserved bytes
  mtd: part: Remove partition overlap checks
  mtd: part: Add sysfs variable for offset of partition
  mtd: part: Create the master device node when partitioned
  mtd: ts5500_flash: Fix typo in MODULE_DESCRIPTION in ts5500_flash.c
  mtd: denali: Disable sub-page writes in Denali NAND driver
  mtd: pxa3xx_nand: cleanup wait_for_completion handling
  mtd: nand: gpmi: Check for scan_bbt() error
  mtd: nand: gpmi: fixup return type of wait_for_completion_timeout
  ...
fs/jffs2/xattr.c