HID: wacom: Read HID_DG_CONTACTMAX directly for non-generic devices
authorJason Gerecke <jason.gerecke@wacom.com>
Wed, 1 Apr 2020 21:23:29 +0000 (14:23 -0700)
committerBenjamin Tissoires <benjamin.tissoires@redhat.com>
Fri, 3 Apr 2020 10:10:22 +0000 (12:10 +0200)
commit778fbf4179991e7652e97d7f1ca1f657ef828422
tree78035e08279b2420b8fb932a2f594c4217369852
parentc101e9bbce4ae2947b35a660f17d617fc3827595
HID: wacom: Read HID_DG_CONTACTMAX directly for non-generic devices

We've recently switched from extracting the value of HID_DG_CONTACTMAX
at a fixed offset (which may not be correct for all tablets) to
injecting the report into the driver for the generic codepath to handle.
Unfortunately, this change was made for *all* tablets, even those which
aren't generic. Because `wacom_wac_report` ignores reports from non-
generic devices, the contact count never gets initialized. Ultimately
this results in the touch device itself failing to probe, and thus the
loss of touch input.

This commit adds back the fixed-offset extraction for non-generic devices.

Link: https://github.com/linuxwacom/input-wacom/issues/155
Fixes: 184eccd40389 ("HID: wacom: generic: read HID_DG_CONTACTMAX from any feature report")
Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com>
Reviewed-by: Aaron Armstrong Skomra <aaron.skomra@wacom.com>
CC: stable@vger.kernel.org # 5.3+
Signed-off-by: Benjamin Tissoires <benjamin.tissoires@redhat.com>
drivers/hid/wacom_sys.c