i40e: get pf_id from HW rather than PCI function
Getting the pf_id from the function number was a good place to start,
but when the PF was setup in passthru mode, the PCI bus/device/function
was virtualized and the number in the VM is different from the number in
the bare metal. This caused HW configuration issues when the wrong pf_id
was used to set up the HMC and other structures. The PF_FUNC_RID register
has the real bus/device/function information as configured by the BIOS,
so use that for a better number. This works in NPAR mode as well.
Change-ID: I65e3dd6c97594890c2bad566b83cc670b1dae534
Signed-off-by: Shannon Nelson <shannon.nelson@intel.com>
Acked-by: Greg Rose <gregory.v.rose@intel.com>
Acked-by: Kevin Scott <kevin.c.scott@intel.com>
Tested-by: Jim Young <jamesx.m.young@intel.com>
Signed-off-by: Jeff Kirsher <jeffrey.t.kirsher@intel.com>